Clean Pin Alert LED and Output

Red flashing LED shows that bar is dirty and needs cleaning. Solid red illumination 

indicates a fault with the high voltage output.

 

„

No light - OK

 

„

Red flashing - Cleaning required

 

„

Red constant - Fault

 
The signal is an open collector output. Open circuit when the system is OK (Flashing 
green LED). Grounded when the Clean Pin alert is active (Flashing red LED) or 
System fault (Solid red LED). 

The output signal is a constant signal irrespective of whether the LED is flashing red 

or constantly red. In either case, the signal alerts the operator to inspect the bar to 
discover what has caused the alert.

External 

Alarm/Lamp/Relay

24

V Max

Output 

External 

Alarm/Lamp/Relay

Output

20m

A Max

Output OFF (= Green LED Flashing) 

Output ON  (= Red LED Flashing or Solid)

Open Collector Alarm output

Содержание Hyperion 971IPS

Страница 1: ...1 Hyperion 971IPS Operating Manual Long Range DC Bar...

Страница 2: ......

Страница 3: ...r to our Head Office or visit www meech com Meech Static Eliminators Ltd 05 04 2013 Contents Introduction 3 Unpacking and Inspection 4 Contents 4 Standard Equipment 4 Optional Equipment 4 Features of...

Страница 4: ......

Страница 5: ...xceptional static control The local LED indicators show the operational status of the bar and advises when the bar requires cleaning Demanding installations can take advantage of the adjustable output...

Страница 6: ...mage is evident do not destroy the carton or packing material and immediately notify the carrier of a possible damage claim Shipping claims must be made by the consignee to the delivering carrier Cont...

Страница 7: ...PS is powered by 24VDC via a 4 pin M8 Connector Overall look The profile of the Hyperion 971IPS bar is rounded with minimal dirt traps making it useful for cleanroom applications The bar has good rigi...

Страница 8: ...efore being powered up Emitter Assembly The emitter assembly is a one piece moulding with a 1mm diameter sharp titanium emitter pin The use of titanium pins has a long history at Meech Extremely hard...

Страница 9: ...r Boost Air Outlets Air Outlets Whilst the long range performance of the Hyperion 971IPS is excellent some installations can require the use of air assistance to get full control of the static This ca...

Страница 10: ...K Flashing green LED Grounded when the Clean Pin alert is active Flashing red LED or System fault Solid red LED The output signal is a constant signal irrespective of whether the LED is flashing red o...

Страница 11: ...collector output signal will activate This can be monitored remotely to alert the operator to attend to the bar Divider The divider used on all Meech pulsed DC bars is an essential feature that ensur...

Страница 12: ...n modern fast machinery Rigid profile Minimises the number of mounting points required Resistive coupling Safe for operators to handle Titanium emitter pins Continue to give good ionisation after year...

Страница 13: ...e mounted securely using all the M4 T bolts provided with the bar Correct positioning of the bar is vital for effective static control Ideally there should be no metallic objects or obstruction betwee...

Страница 14: ...rt range over a web or sheet the bars must be positioned away from surfaces and rollers as shown in the following diagrams Your Meech distributor will be able to assist with questions regarding positi...

Страница 15: ...he bar is grounded using this post in addition to using a grounded 24VDC supply 971IPS 220V AC 24V DC 0V Power Supply Grounded 0V Grounding using ground post Connection to the 971IPS is via an industr...

Страница 16: ...dard IEC C13 mains socket and a 2000mm HT cable to M8 Connector A break out wire from the switchmode power supply provides the Clean Pin Alert output signal Connection using customer s own power suppl...

Страница 17: ...d up on the emitter pins and upon the body of the ioniser This will cause a reduction in performance Typically weekly cleaning is sufficient However equipment used in some heavy contamination areas su...

Страница 18: ...ned with a small amount of IPA or methylated spirits is recommended Let dry for a minute before turning back on If on inspection the emitter pins of the bar are very dirty or damaged they should be re...

Страница 19: ...rranty The Meech 971IPS Bar is warranted by Meech Static Eliminators Ltd to the original purchaser against defects in material and workmanship for one year after purchase Should any malfunction occur...

Страница 20: ...al Open collector Vmax 24V Imax 20mA Output Frequency Default Setting 1Hz Adjustable with BarMaster from 1Hz to 20Hz Output Balance Default Setting 60 40 Pos Neg Adjustable with BarMaster from 80 20 t...

Страница 21: ...19 Health and Safety Emission of Ozone Considerably below international standard of 0 1ppm...

Страница 22: ...20...

Страница 23: ......

Страница 24: ...ewpark Drive Norton OH 44203 USA Tel 1 330 564 2000 1 800 232 4210 Fax 1 330 564 2005 email info meech com Meech Static Eliminators Shanghai Co Ltd 7G 7F LP Tower 25 Xiangfeng Road 201103 Shanghai Chi...

Отзывы: