9
The open collector output has voltage and current limits of:
V
max
= 24V
I
max
= 20mA
Frequency Indicator
A red/green LED flashes in time with the HT outputs, giving a visual indication of the
bar’s setup
Remote Signal
In the case of the Cleaning Alert LED activating, the open collector output signal will
activate. This can be monitored remotely to alert the operator to attend to the bar.
Divider
The divider used on all Meech pulsed DC bars is an essential feature that ensures
good operation in dirty, factory environments. To maximise the interval between
cleaning the 971IPS bar features a divider to increase the surface tracking distance
between the two rows of high voltage pins. It is important to clean this area during
cleaning operations.