21
Warning
Do not reset the Ion Reference without cleaning the ionising bar first. Resetting the Ion
Reference with a low or 0% reading will provide a green LED, but will only mask any
problem with the system.
The 314IPS requires a grounded 24V DC supply. The 0V line must be connected
to ground. Failure to do so, will result in damage to the bar or the 24V supply
and will void the warranty.
Troubleshooting
Solid Green
Light
Meaning
In normal operation the LED on the bar will
illuminate Green. This indicates that the bar
is operating correctly with good ionisation
performance.
No LED
Meaning
No Power to the bar.
Action
Check 24V power supply over pins 1 and 3.
(Brown and Blue wires)
Flashing Green
LED
Meaning
BarMaster remote programmer is connected.
Action
After programming, reconnect directly to the
power supply to resume normal operation.
Flashing Red
Likely cause Contamination causing a drop in performance.
Action
Switch off power supply and clean as
described in the Maintenance section.
Solid Red
Likely cause Abnormal output current detected.
Action
Check installation for metallic objects on the
emitter pins.
Should the solid Red LED persist, Contact
your Meech distributor.