6
Control Adjustments
There are three adjustments that can be made on the Power Supply; BALANCE,
RATE and POWER.
The BALANCE of positive and negative ion output can be adjusted to increase polarity
bias by simply turning the balance control towards either positive (right) or negative
(left).
When set to mVE or -VE the split is 20/80 - ie at maximum positive 80% of
the ions are positive and 20% of the ions are negative (or vice versa).
The RATE of pulse frequency can be adjusted from 0.5 Hz to 20Hz. The lower the
frequency (RATE) the greater the range (ie distance over which the ionisation will
travel). A setting of 5 to 10Hz is recommended for most applications.
The POWER or output voltage of the unit may also be adjusted by turning the power
control knob. The output voltage may vary from a minimum of 4kV to a maximum of
8kV.
The purpose of these adjustments is to give total versatility to the positioning of the
ionising product attached to it.
Remember it is important to verify calibration after any adjustments and before using
your ioniser around sensitive electronics.