6
The information displayed is:
1. Power:
Peak momentary output voltage in kV.
2. Rate:
Frequency of the output in Hz. The output frequency is
operator set according to the type of installation and the
ionising equipment connected to the 977HL.
3. Balance:
Balance of the Positive and Negative outputs in Percent.
The balance can be biased to positive or negative to give the
most accurate neutralisation.
4. Ion Output: Graphical display of system performance with percentage
value.
*Without Feedback sensor bar connected. See Feedback section on page 18 for further information.
Controls
Four buttons control the 977HL:
Up:
Moves the cursor up and increases numerical values
Menu: Enters and exits the main system menu
Down: Moves the cursor down and decreases numerical values
Tick:
Accepts and stores the displayed value.