6
Compressed Air
Connect your air supply directly to the Model 261v2 using 6mm push fit hose. A local
compressed air shut-off valve should be installed (not supplied). For most applications,
the compressed air supply should be regulated to 30 psi (2 bar). Maximum operating
pressure is 100psi (7 bar).
Pumped Air
Versions of the nozzle with ¼” bsp inputs can be used with low pressure pumped air.
Ensure that any fittings used have as side a bore as possible, to maximise the air-flow.
Interlocking of High Voltage
We recommend interlocking the state of the high voltage output to the running state
of the machine. This can be achieved by switching the power supply to the Pulsed
DC controller or by using the remote on/off input built into all Meech Pulsed DC
controllers. See the relevant operating manual for more information.
For Best Results
1.
Keep the target area clear and free from obstructions to the ion flow.
2. Keep the work area clear of all static generative materials.
3. Use only approved static control grounding methods and material handling
equipment.
4. By properly using ionised air, all static potentials in the work area are greatly
reduced, even when humidity levels decrease.