EMPTYING THE TANK
Empty any condensed water every day by
opening the emptying valve (on the bottom of
the pressure container).
1. Check that the compressor is switched off
"OFF".
2. Tilt the compressor, by holding the
handle, towards the emptying valve.
3. Turn the emptying valve to open.
4. Keep the compressor tilted to empty all
the moisture.
5. Close the drain valve.
NOTE:
The condensate in the pressure container
contains oil residue. Recycle condensate at
the local recycling centre.
STORAGE
• Pull out the plug and vent the machine
and pneumatic tool. Store the compressor
where it cannot be used by unauthorised
persons.
• Store the compressor is a dry place, out of
reach of unauthorised persons. Store the
compressor upright.
TROUBLESHOOTING
See next page.
RECOMMENDED PRESSURE
Blowing
How to use
Operating
pressure
(Bar)
Blowing dust off objects.
8
Blowing dust off measuring
equipment.
4
MAINTENANCE
NOTE:
• Always pull out the plug before cleaning
and maintenance.
• Wait until the compressor has cooled
completely! Risk of burns.
• Release the pressure in the container
before cleaning and maintenance.
• Do not use solvent, flammable or toxic
liquid to clean the blow gun.
• Keep the safety devices free from dust and
dirt. Wipe the machine with a clean cloth,
or blow clean with compressed air at low
pressure.
• It is recommended to clean the machine
every time it has been used.
• Clean the machine at regular intervals
with a damp cloth and a little soft soap.
Do not use detergent or solvent. They can
damage the plastic parts on the machine.
Make sure that no liquid gets into the
machine.
• Disconnect the hose and spray gun from
the compressor before cleaning (fig. 5).
Do not clean the compressor with water
or solvent.