17
English
8.
Protection against empty tank: As soon as the tank runs empty, the display flashes waterless
("tank is empty"). The device switches off automatically. The timer and humidistat (humidity
controller) settings are also deleted. Once the device has been refilled with water, the
function settings can be entered again.
3.4 Faults and Fault Remedying
•
Device will not switch on (LED not illuminating):
Plug in the plug; Check power circuit, socket
and fuse.
•
No mist (LED lights up red):
Fill water tank.
•
No mist although tank full:
Increasing mist intensity; Place device on a level surface; Clean
atomiser and generator using provided brush and fill tank with clean water; Rinse device with
clean water.
•
White deposits:
Use clean water or at least 1/2 distilled water / 1/2 fresh tap water. If a fault
cannot be remedied using the described method, please contact your service centre
.
3.5 Operating time
•
Operation time is approx. 15 hours at the maximum setting (300 ml/h) with 4500 ml of water.
4 Miscellaneous
4.1 Cleaning and maintenance
•
During everyday use it is advisable to give the device a thorough cleaning at least every
three days. If there are extended periods of non-use, drain the device and tank to prevent
contamination /algae from the outset. Disinfect with alcohol now and then. Also clean device
before and after long storage periods.
•
Before cleaning the device, make sure that it is turned off and the mains plug is removed from
the socket.
•
Remove the water tank from the device and empty it.
•
Clean the outside of the unit with a soft, damp cloth.
•
Please do not use any aggressive substances for cleaning, such as scouring cream or other
detergents, as these may damage the surfaces and reduce the atomisation effect.
•
You can rinse out the water tank with hot water (>65 °C) or an alcohol of at least 75 % vol.
The atomiser chamber should be cleaned using an alcoholsoaked cloth and cotton bud. Take
care to ensure that no water gets inside the humidifier.
•
The ultrasound generator is the most sensitive component in the device. It is important for it to
be kept clean and handled with care. Please use the pro-vided brush
q
to remove deposits and
dirt particles from the outlets. Never clean the ultrasound generator using metal objects.
•
If you do not intend to use the unit for an extended period of time, empty any remaining water
from the tank and dry off the unit.
•
When cleaning the unit, rinse the filter
w
in clean water. If you are not using the unit for an
extended period, store the filter separately so that it can dry.
•
Store the unit in a cool, dry place, preferably in its original packaging.
•
Remove cap from underside of the water tank and store separately to prevent sleeve gasket
from sticking.
88830_PR-H90_DE-GB_NL_FR_ES_GR_IT_01072016_Kompakt-GA 01.07.16 17:13 Seite 17
Содержание PR-H90
Страница 44: ...44 K LOT...
Страница 45: ...45 1 8 MEDISANA...
Страница 46: ...46 MEDISANA 2 PR H90 MEDISANA MEDISANA PR H90 2 1 1 MEDISANA PR H90 1 1 1...
Страница 47: ...47 2 2 40 55 30 m2 8 55 3 MEDISANA 1 2 m 3 1 5 C 5 40 C 80 40 C 0 3 2 2 4 3 4 5 l 4 1 2...
Страница 49: ...49 8 Waterless Humidistat 3 4 LED H LED 1 2 1 2 3 5 300 ml h 4500 ml 15 4 4 1 65 C 75 q w...
Страница 50: ...50 4 2 w PR H90 4 4 4 100g 2000ml 60 C 3 4 3...