78
Step
1
2
3
Mode
Battery
charge
test
Constant
current
charging
Constant
voltage
charging
Battery
voltage
test
Trickle
charging
2
A:
At a
voltage of
more than
8 V, the
battery will
be detect-
ed as a 12 V
battery.
B:
At a volt-
age of be-
tween 8 V
and 10.5V
trickle
charging is
activated
(1 A pulsed
charging
until the
voltage
reaches
10.5V).
C:
If a volt-
age of
10.5 V
is not
achieved
within 30
min, the
battery is
recognised
as defec-
tive.
1A constant
current
load up to
14.4 V
-
If after 1
minute the
voltage:
A:
drops
below 12 V,
the battery
is recog-
nised as de-
fective
B:
is be-
tween 12–
12.8 V, the
charg-
er switch-
es to trickle
charge
C:
is over
13.7 V, trick-
le charg-
ing starts as
soon as the
voltage falls
back under
12.8 V
1 A: Con-
stant volt-
age charg-
ing
If the
charge falls
below 0.2 A,
the charg-
ing process
stops until
the voltage
drops be-
low 13.7 V
12.8 V/1 A
Charging
will contin-
ue
3
4 A con-
stant cur-
rent charg-
ing up to
14.8 V, then
constant
voltage
14.4 V con-
stant volt-
age until
the charge
reaches
0.65 A
4
4 A con-
stant cur-
rent charg-
ing up to
14.8 V, then
constant
voltage
14.8 V con-
stant volt-
age until
the charge
reaches
0.65 A