spirodoc

 

 

 

SPIRODOC

 

 

 

cod. 980156 

 Rev 2.4   

 

EN 17/46 

 

User manual 

ICON 

DESCRIPTION 

 

To send data to a mobile phone via Bluetooth 

 

To access the database of the performed tests. 

 

To search a test with the date of birth of a patient 

 

To search a test starting from a specific date onwards..(partial database) 

 

To flick through a database from beginning to end and viceversa (complete database) 

 

Patient search through family name. 

 

Male sex patient selection  

 

Female sex patient selection  

 

To perform tests without having to insert patient data 

 

To access all oximetry test options / To perform an SpO2/BPM test 

 

To perform an SpO2/BPM test 

 

To perform a sleep oximetry test 

 

To perform a 6MWT/ to move on to the walking phase of the test 

 

Tom move on to the recovery phase of the 6MWT 

 

To access spirometry testing type 

 

to perform a forced vital capacity test FVC/search FVC tests in memory 

 

To perform a slow vital capacity spirometry test VC/ search VC tests in memory 

 

To perform a maximum voluntary ventilation spimetry test MVV/ search MVV tests in 
memory 

 

To perform a spirometry test with a broncodilator 

 

Search in memory oximetry tests lasting more than 12 hours 

 

To print via Bluetooth connection 

 

To view the pletismographic curve in real-time while performing an oximetry test 

 

To check the alarms and alarm thresholds during oximetry testing  

 

To check the alarms and alarm thresholds during oximetry testing when at least one 
parameter is turned OFF 

 

Enabled alarm waring during oximetry testing 
To temporarily disable the alarm 

 

Disabled alarm warning during oximetry testing 
To temporarily enable the alarm 

 

Symptoms selection in 

PATIENT 

mode 

 

2.6 

Service menu  

To enter the service menu touch the display when the following icon appears 

 and keep pressing for a few seconds. 

The service menu shows different items according to whether the device is set to either Patient or D

octor mode; The item “

SPIRODOC

 

mode” is the 

first one displayed in both modes. The configuration of the item menus for the two modes is the following:  
 

Patient Mode 

Doctor Mode 

  Doctor/Patient 

  Turn-ON Mode 

  Patient data  

  OXIMETRY setup 

  Set questions 

  Set symptoms  

  Personal best 

  Select predicted 

  Select standard 

  Select turbine 

  Turbine calibration 

  Select language 

  DATE format 

  UNIT  format 

  Delete memory 

 

  Doctor/Patient  

  Change date/time 

  LCD settings 

  Bluetooth settings 

  Turn-ON mode 

  Oximetry setup  

  Select predicted 

  Select standard 

  Set parameters 

  Select turbine 

  Turbine calibration 

  Select language 

  Date format 

  Unit format 

  Delete memory 

  Info firmware 

  Demo Oxi 

Содержание spirodoc

Страница 1: ...spirodoc SPIRODOC cod 980156 Rev 2 4 EN 1 46 User manual User manual rev 2 4 Issue date 10 04 2014 Approval date 10 04 2014...

Страница 2: ...23 2 7 Patient Data 24 2 7 1 Inserting data of a new patient 24 2 7 2 Patient data modification 24 2 8 Visualization of memory data 24 2 8 1 Database research modality 24 2 8 2 Visualization of databa...

Страница 3: ...mir spirometry com MIR accepts no responsibility for any loss or damage caused by the user of the device due to instructions contained in this Manual and or due to incorrect use of the product Please...

Страница 4: ...e a spirometry test is made The user is responsible to assess both the mental and the physical condition of the patient in order to perform a proper test furthermore in the evaluation of test results...

Страница 5: ...r the correct functioning and possibly cause damage The presence of any impurities such as hair sputum threads etc within the body of the turbine sensor may seriously compromise measurement accuracy 1...

Страница 6: ...with the correct operation of the device For this reason certain minimum clearances a few meters should be observed when high frequency appliances such as a TV radio portable phone etc and other elec...

Страница 7: ...rly aligned If the leads are inverted an inverse polarity connection may provoke acid leakage overheating smoke breakage and or fire Do not connect the battery pack leads to a wall socket or to the ca...

Страница 8: ...tandard this product and its component parts are of type BF and therefore protected against the dangers of direct and indirect contact with electricity 1 5 4 Warning symbol for the USB To connect to o...

Страница 9: ...ved receive an explanation of the ESD warning symbol and training in ESD precautionary procedures the electrostatic discharge is defined as an electric charge at rest It is the sudden flow of electric...

Страница 10: ...or alternatively to the personal best values from the clinical history of the subject The personal best values can vary considerably from the predicted values which are taken from healthy subjects SPI...

Страница 11: ...nt system Bi directional digital turbine Temperature sensor semiconductor 0 45 C Measurement principle Infrared interruption Volume range 10 L Flow range 16 L s Volume accuracy 3 or 50 mL Flow accurac...

Страница 12: ...to administer to the patient O2 percentage of oxygen administered to the patient before test L min SPO2 Base SPO2 base value for the SPO2 and ODI tests BPM Base BPM base value for the SPO2 and ODI te...

Страница 13: ...es SPO2 start 6MWT no SPO2 end 6MWT no BPM end 6MWT no SPO2 Base 6MWT no BPM start 6MWT no T Baseline 6MWT no T Walking 6MWT no T Recovery 6MWT no Distance 6MWT no T2 SPO2 T2 SPO2 6MWT yes T4 SPO2 T4...

Страница 14: ...ecial alarm frequency in the case of either SpO2 or cardiac pulse going outside of the programmed levels of alarm Beep with special alarm frequency during oximetry measurement in the case of a low bat...

Страница 15: ...llows access to all functions by simply touching the display The controls on the touch screen change dynamically based on the functions performed To access a specific function touch the corresponding...

Страница 16: ...ith the symbol This image indicates that the battery pack is fully charged 6 indicators A drop of the battery pack charge is displayed with a reduction of the indicators 2 4 Main screen On the main sc...

Страница 17: ...via Bluetooth connection To view the pletismographic curve in real time while performing an oximetry test To check the alarms and alarm thresholds during oximetry testing To check the alarms and alarm...

Страница 18: ...egin There are four phases as follows Touch three times the top left hand point of the display Touch three times the top right hand point Touch three times the bottom right hand point Touch three time...

Страница 19: ...a menu appears to set the day and time that the device will turn on and off If turn ON mode was previously enabled and the user turns on the device at a different time from that of the programmed tim...

Страница 20: ...beep during oximetry testing WARNING The heart rate tone beep is always disabled during sleep oximetry testing please view paragraph 3 13 2 Default alarms This function allows to restore all default...

Страница 21: ...alibration allows to insert new calculated values to perform a new calibration A password is required to access this option insert the following password by touching the numbers starting from left to...

Страница 22: ...he item Configuration and insert the following password 1 2 2 3 3 3 The service menu will display the following items Doctor Patient Turn ON mode Patient data Oximetry setup Set questions Set symptoms...

Страница 23: ...ot be accepted This means that the device is not capable of correcting such a large calibration error In this case Check the correct functioning of the SPIRODOC with a new turbine and or Clean the tur...

Страница 24: ...ian Caucasian 100 Mexican American Oriental 100 Afro American Hong Kong Chinese 100 Other Giapanese 89 polinesian 90 North Indian 90 South Indian 87 Pakistani 90 African descendant 87 Aboriginal 85 Wh...

Страница 25: ...t specific date Test session in Patient Mode refers to spirometry PRE tests and oximetry tests performed within a 20 minute time span A new session is activated upon turning on the device if the time...

Страница 26: ...s can be seen on the screen to the right If a patient has instead performed a test in the current session and previous tests are archived the following screenshot is displayed 2 10 PC On line mode con...

Страница 27: ...tory parameters FIVC FIV1 FIV1 PIF are not of interest The optional initial inspiration phase can also be performed before inserting the mouthpiece in the mouth After inspiring slowly and deeply the f...

Страница 28: ...results from the PRE test as well as the relevant predicted values The following tests made by the patient show the following parameters Those values related to the test performed Those values related...

Страница 29: ...s shown Blow out all air in lungs Between tests the SPIRODOC checks the repeatability of the following parameters PEF repeatable when the difference between the two largest PEF is 0 67 L s VC repeatab...

Страница 30: ...message will appear Low battery level Touch the ESC icon to exit the test otherwise after a seconds will start the test In the event that a test is interrupted due to a complete battery discharge the...

Страница 31: ...case the icon will be shown as to then return to the previous icon when the two minutes are over For information concerning the proper setup of this function please refer to paragraph 3 6 WARNING A t...

Страница 32: ...6 minutes are up the device will automatically move on to the recovery stage and the timer will be reset to zero again Recovery stage The duration of this stage is entirely up to the doctor and it is...

Страница 33: ...agraph 3 13 1 To perform this test touch the from the main screen and subsequently select the test with the icon After approximately 5 minutes from the beginning of the test the SPIRODOC will automati...

Страница 34: ...The materials used for manufacturing the sensor are NATURAL LATEX PROTEIN FREE and are subject to biocompatibility tests WARNING The adult single patient sensor is ideal for patients weighing more th...

Страница 35: ...ximetry test walk test sleep oximetry send data via Bluetooth WARNING Spirometry test results do not include any automatic interpretation compared with the predicted values as no patient anthropometri...

Страница 36: ...Vista and Seven To avoid making any errors at this stage please read the Advanced section of the winspiroPRO User Manual carefully 3 4 Internal software upgrade SPIRODOC internal software can be upgr...

Страница 37: ...ne is still malfunctioning please replace it with a new one WARNING Do not carry out any cleaning procedures when using disposable turbines a new disposable turbine must be used for every new patient...

Страница 38: ...spiroPRO software For further information consult the winspiroPRO manual available on line within the software itself Spirometry test results are unreliable The turbine may contain dirt or foreign mat...

Страница 39: ...irometer Oximeter Brandname MIR Medical International Research Device name spirodoc Class IIa Complies with the Essential Requirements of directive 93 42 EC concerning Medical Devices and its amendmen...

Страница 40: ...ation If the product is utilised differently from the use described in the User s Manual If any alteration adjustment modification or repair has been carried out by personnel not authorised by the man...

Страница 41: ...spirodoc SPIRODOC cod 980156 Rev 2 4 EN 41 46 User manual ANNEX 1OXIMETRY TEST REPORTS EXAMPLES...

Страница 42: ...spirodoc SPIRODOC cod 980156 Rev 2 4 EN 42 46 User manual...

Страница 43: ...spirodoc SPIRODOC cod 980156 Rev 2 4 EN 43 46 User manual...

Страница 44: ...spirodoc SPIRODOC cod 980156 Rev 2 4 EN 44 46 User manual ANNEX 2SPIROMETRY TEST REPORT EXAMPLE...

Страница 45: ...for input output lines Mains power quality should be that of a typical commercial or hospital environment Surge IEC 61000 4 5 1 kV differential mode 2 kV common mode Not Applicable Mains power quality...

Страница 46: ...OC The SPIRODOC is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the SPIRODOC can help prevent electromagnetic interfe...

Отзывы: