Mediana HeartOn T15 Скачать руководство пользователя страница 13

 

 

11

 

 

Table 7. Scenario (continued) 

 

Scenario 6 

Scenario 7 

Scenario 8 

Scenario 9 

Scenario 10 

1* 

Checking patient’s 
consciousness 

Checking 
patient’s 
consciousness 

Checking patient’s 
consciousness 

Checking patient’s 
consciousness 

Checking patient’s 
consciousness 

2*  Calling to EMS   

Calling to EMS 

Calling to EMS 

Calling to EMS 

Calling to EMS 

3*  Open the airway 

Open the airway 

Open the airway 

Open the airway 

Open the airway 

4*  Checking breath 

Checking breath 

Checking breath 

Checking breath 

Checking breath 

5  Attaching pad 

Attaching pad 

Attaching pad 

Attaching pad 

Attaching pad 

Warning: Do not 
touch with the 
patient 

Warning: Do not 
touch with the 
patient 

Poor Pads 
connecting 

Warning: Do not 
touch with the 
patient 

Simulating motion 
artifact 

Analyzing rhythm 

Analyzing rhythm  Warning: Do not 

touch with the 
patient 

Analyzing rhythm 

Warning: Do not 
touch with the 
patient 

Simulating 
Shockable rhythm 

Simulating 
Shockable 
rhythm 

Analyzing rhythm 

Simulating 
Shockable rhythm 

Analyzing rhythm 

Delivering shock   

Delivering shock 

Simulating 
Shockable rhythm 

Delivering shock 

Simulating 
Shockable rhythm 

10 

CPR(30:2, 
5CYCLE) 

CPR(30:2, 
5CYCLE) 

Delivering shock 

CPR(30:2, 
5CYCLE) 

Delivering shock 

11 

Warning: Do not 
touch with the 
patient 

Warning: Do not 
touch with the 
patient 

CPR(30:2, 
5CYCLE) 

 

CPR(30:2, 
5CYCLE) 

12 

Analyzing rhythm 

Analyzing rhythm  Warning: Do not 

touch with the 
patient 

 

Warning: Do not 
touch with the 
patient 

13 

Simulating 
Shockable rhythm 

Simulating 
Shockable 
rhythm 

Analyzing rhythm 

 

Analyzing rhythm 

14 

Delivering shock 

Delivering shock 

Simulating 
Shockable rhythm 

 

Simulating non-
shockable rhythm 

15 

CPR(30:2, 
5CYCLE)   

CPR(30:2, 
5CYCLE)   

Delivering shock 

 

CPR(30:2, 
5CYCLE) 

16 

Warning: Do not 
touch with the 
patient 

Warning: Do not 
touch with the 
patient 

CPR(30:2, 
5CYCLE) 

 

Low Battery 

17 

Analyzing rhythm 

Analyzing rhythm  Warning: Do not 

touch with the 
patient 

 

 

18 

Simulating non-
shockable rhythm 

Simulating non-
shockable rhythm 

Analyzing rhythm 

 

 

19 

CPR(30:2, 
5CYCLE) 

CPR(30:2, 
5CYCLE) 

Simulating non-
shockable rhythm 

 

 

20 

 

Warning: Do not 
touch with the 
patient 

CPR(30:2, 
5CYCLE) 

 

 

Содержание HeartOn T15

Страница 1: ...rtOn T15 AED Trainer Part Number A7427 0 Revised Date 0814 Copyright 2014 All rights reserved www medianadefib co uk Distributed by Reliance Medical LTD West Avenue Talke Stoke on Trent Staffordshire...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...control 13 List of Components 13 Figures Figure 1 HeartOn T15 Components and Controls 3 Figure 2 HeartOn T15 G4 Components and Controls 3 Figure 3 Side and bottom panel of AED Trainer 4 Figure 4 Train...

Страница 4: ...ared remote control The remote control gives the instructor the ability to alter training scenarios while in progress to test student response l AED Trainer is pre configured with 10 training scenario...

Страница 5: ...3 Description of the AED Trainer Components and Controls Figure 1 HeartOn T15 Components and Controls Figure 2 HeartOn T15 G4 Components and Controls 1 3 2 4 5 6 7 9 8 1 2 3 4 5 6 7 9 8...

Страница 6: ...ult and pediatric patient mode by pushing the patient mode switch 6 Shock button When preparation for electric shock is completed press the flashing button and then the AED delivers the simulated shoc...

Страница 7: ...or Pediatric pads Analyzing heart rhythm Do not touch the patient Shock advised Charging Do not touch the patient or Analyzing heart rhythm Do not touch the patient No shock advised Press the red fla...

Страница 8: ...ent Shock advised Charging Do not touch the patient or Analyzing heart rhythm Do not touch the patient No shock advised Press the red flashing button now Deliver shock now Shock delivered or Press the...

Страница 9: ...ng will be stored when the AED cover is closed Shockable rhythm button Non shockable rhythm button Poor pad condition recovery button Motion artifact button Poor pad condition button Not used in Heart...

Страница 10: ...nging pad condition is recovered to normal condition Not used in HeartOn T15 and HeartOn T15 G4 Simulate the Low battery condition and indicate Low battery condition on the status indicator When the b...

Страница 11: ...he desired scenario and then perform the download to the custom scenario 1 2 or 3 7 After completion of downloading turn off the AED by closing the AED cover and disconnect the USB mini B cable 8 Set...

Страница 12: ...ring shock Delivering shock Simulating Shockable rhythm Delivering shock CPR 30 2 5CYCLE 10 CPR 30 2 5CYCLE CPR 30 2 5CYCLE Delivering shock CPR 30 2 5CYCLE 11 Warning Do not touch with the patient Re...

Страница 13: ...zing rhythm Simulating Shockable rhythm Analyzing rhythm 9 Delivering shock Delivering shock Simulating Shockable rhythm Delivering shock Simulating Shockable rhythm 10 CPR 30 2 5CYCLE CPR 30 2 5CYCLE...

Страница 14: ...8 CPR 30 2 5CYCLE HeartOn T15 only The MEDIANA OPTION button press is ignored on HeartOn T15 G4 Note When the standard scenario is selected AED trainer starts the simulation from Analyzing rhythm step...

Страница 15: ...imum Current 500mA l Size 240mm 294mm 95mm l Weight 1 44kg including the battery Environmental Conditions Operation l Temperature 0 to 43 C 32 to 109 4 F l Relative Humidity 5 to 95 Non condensing l A...