![Media5 Mediatrix C710 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/media5/mediatrix-c710/mediatrix-c710_hardware-installation-manual_1760477028.webp)
Chapter 3 - Powering on the Mediatrix C7 Series
Indicators (LEDs)
16
Mediatrix C7 Series – Digital Gateway
Verifying the Installation
There are a few ways to verify that the Mediatrix C7 Series is properly connected to the IP network and is
working:
By contacting it with a SNMP browser
By contacting it via the CLI
By contacting it via a web browser
By pinging it
These procedures assume that you know the IP address of the Mediatrix C7 Series you want to verify. If the
Mediatrix C7 Series does not respond, do the following:
Verify that the LAN and WAN cables are securely connected to the Mediatrix C7 Series and to
the network connectors.
Be sure that you did not connect crossover network cables.
Verify the state of the IP network to ensure it is not down (the
ETH1 or ETH2
LED should be
ON or blinking).
Indicators (LEDs)
The indicators (LEDs) of the Mediatrix C7 Series are described in
“Mediatrix C7 Series Connectors and
.
LED Patterns – Specific Conditions
describes the different states a Mediatrix unit can have and their associated LED patterns.
*#*1
MAC address of the Mediatrix C7 Series.
Table 5:
Vocal Unit Information (Continued)
Digits to Dial
Information Vocally Sent by the Mediatrix C7 Series
Table 6:
LED Patterns
Condition
Description
LED Pattern
RestartPending
Triggered when the
RESET/DEFAULT
button is
pressed in the
ResetPending
state. The unit
prepares for a physical shutdown and restart.
Power
LED:
•
blinking, 1Hz, 50%
duty
All other LEDs:
•
OFF
RecoveryPending
Triggered when the
RESET/DEFAULT
button is
pressed at start-time or for at least 7 seconds.
All LEDs:
•
blinking, 1Hz, 50%
duty
DefaultSettingsPending Triggered when the
RESET/DEFAULT
button is
not released while in
ResetPending
state.
At run time, if the
RESET/DEFAULT
button is
released within 5 seconds, the unit applies
default settings, otherwise the action is
cancelled and the unit goes back to the
operation mode state or it resets.
At start time, the unit stays in this state until the
RESET/DEFAULT
button is released. The unit
then applies the default settings and restarts.
All LEDs:
•
steady ON
Содержание Mediatrix C710
Страница 6: ...Contents vi Mediatrix C7 Series...
Страница 12: ...Preface About this Manual End User Technical Support xii Mediatrix C7 Series Digital Gateway...
Страница 16: ...Chapter 1 Overview Mediatrix C7 Series Connectors and Indicators 4 Mediatrix C7 Series Digital Gateway...
Страница 35: ...Disclaimers Hardware Installation Guide Mediatrix C7 Series Digital Gateway 23 RoHS China...
Страница 48: ...Appendix C Glossary Wide Area Network WAN 36 Mediatrix C7 Series Digital Gateway...
Страница 50: ...Appendix D List of Acronyms 38 Mediatrix C7 Series...