USER`S MANUAL
ME-TUN
File: ME-TUN Manual E.DOC
MEDIA ENGINEERING
page 8/29
A.3. SETTING THE SAMPLING RATE FOR THE DIGITAL AUDIO OUTPUT
The AES/EBU digital audio output on the rear side of the ME-TUN is featuring a sampling
rate of 48kHz. This sampling rate is factory set and marked on the rear panel as such.
In case this is not the propre sampling rate for a given application it’s possible to choose one
of three other values:
•
32
kHz
•
44.1
kHz
•
48
kHz
•
96
kHz
In order to change the sampling rate one needs to change the setting of two jumpers which
are located inside the ME-TUN. Please refer to the procedure as described herewith:
1. Carefully study the SAFETY CONDITIONS in chapter A.1. on page 5
2. disconnect all cables from the ME-TUN. Make shure there is no power line
connected anymore and the power switch is off.
3. loosen the three black M3 screws on the top front of the ME-TUN with the
help of an appropriate 2.0mm PHILIPS screw driver in order to remove the
cover.
4. put the three screws beside for they will be used again at the end
5. shift the cover 10mm to the rear and lift it off
6. locate the output amplifier board (called TADOBOARD, 72mm x 132mm) at
the very back totally to the right.
7. loosen the three black M3 screws holding down the output amplifier board
with the help of an appropriate 2.0mm PHILIPS screw driver
8. put the three screws beside for they will be used again at the end
9.
with gentle force and a slight left to right rocking unplug and remove the board
in a straight vertical direction