Lamps
Causes
Remedy
6 lamps
The S180/200 is
prevented from driving.
Inhibit 2 is active. This
may be due to the
battery charger being
FRQQHFWHGWKHSOXJWR
the thermal switches
EHLQJGLVFRQQHFWHGD
fault in the thermal switch
or the Mini Crosser is
overheating.
The Mini Crosser will turn
itself off automatically
after it has been
stationary for 10 minutes.
The battery indicator
ÀDVKHVZLWKODPSVDWD
rate of about 3 seconds.
Stop the unit and wait 3-5
minutes before restarting.
Turn the key to 0 and then
to 1 to reset the fault.
Contact supplier.
7'DJDLQ
the key must be turned to
position 0 and back to I.
7 lamps
Accelerator fault.
Make sure that the
accelerator is in neutral
when the Mini Crosser is
turned on.
8 lamps
Controller fault.
Contact supplier.
9 lamps
Poor connection to motor
brake.
Magnetic brake is
disengaged.
Check the connections
IURPEUDNHWRFRQWUROOHURU
push the brake lever up.
Check that the vehicle is
not disengaged.
10 lamps
The controller has been
supplied with a high
voltage in excess of 38 V.
Usually seen in the case
of a poor connection.
Check all connections
from the batteries to the
controller.
Running lights
Charger is connected.
Remove charger.