![MEDAP 5752 4916 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/medap/5752-4916/5752-4916_operating-instructions-manual_1759331011.webp)
Introduction
Basic requirements
GA 5752 4981 GB 15
11
1
The product is available in the following versions:
• LS FLOW O 15 Wall DIN (REF 5752 4916)
• LS FLOW O 15 Wall DIN P5 (REF 5752 5705)
• LS FLOW O 15 Wall MEDAP (REF 5752 4917)
• LS FLOW O 15 Wall BOC (BS 5682) (REF 5752 4921)
• LS FLOW O 15 Wall Air Liquide (NF S 90-116) (REF 5752 5161)
• LS FLOW O 15 Wall AGA (SS 8752430) (REF 5752 5162)
• LS FLOW O 15 NIST connection, equipment rail (REF 5752 5301)
• LS FLOW O 15 NIST connection, equipment rail P5 (REF 5752 5704)
• LS FLOW O 15 NIST connection, screw connection (REF 5752 5708)
• LS FLOW O 05 Wall DIN (REF 5752 5304)
• LS FLOW O 05 NIST connection, equipment rail (REF 5752 5305)
• LS FLOW O 01 Wall DIN (REF 5752 5306)
• LS FLOW O 01 NIST connection, equipment rail (REF 5752 5307)
• LS DFLOW O 15 Wall DIN (REF 5752 4919)
• LS DFLOW O 15 Wall DIN P5 (REF 5752 5702)
• LS DFLOW O 15 Wall MEDAP (REF 5752 5706)
• LS DFLOW O 15 Wall AGA (SS 8752430) (REF 5752 5183)
• LS DFLOW O 15 NIST connection, equipment rail (REF 5752 5302)
• LS FLOW A 15 Wall DIN (REF 5752 5235)
• LS FLOW A 15 Wall DIN P5 (REF 5752 5703)
• LS FLOW A 15 Wall MEDAP (REF 5752 5450)
• LS FLOW A 15 Wall AGA (SS 8752430) (REF 5752 5240)
• LS FLOW A 15 NIST connection, equipment rail (REF 5752 5303)
• LS FLOW A 15 NIST connection, screw connection (REF 5752 5709)
• LS DFLOW A 15 Wall DIN (REF 5752 5607)
• LS DFLOW A 15 NIST connection, equipment rail (REF 5752 5608)
1.5.5
Interface description
All devices and accessories which are combined with the tapping unit must be listed in the
accessories list or meet the specifications of the interface description. The configuration of the
overall system as well as the functional testing are subject to the overall responsibility of the
medical staff. Functionality and suitability of the connected accessory for each intended
application must be checked by the operator before every use. This includes the functionality of
the connector components, its air tightness and suitability regarding material properties, working
pressure and flow rate.
1.5.5.1
Approved interface for compressed gas supply
In order to supply compressed gas, the tapping unit is connected to the central medical gas
supply system (CGSS) with a pressure of 300 - 550 kPa (P5 versions: 500 kPa).
The pressure in the supply line must be indicated and in the event of improper functioning must
be limited to 1000 kPa by an integrated pressure-relief valve.
1.5.5.2
Flowmeter outlet
The internal thread on the accessory must match the external thread on the flowmeter (UNF
9/16" 18 gear). Ensure that the connection between the flowmeter and the accessory is leak-free.