Medallion MBP20LB Скачать руководство пользователя страница 8

8

105736

VENT-FREE PROPANE/LP GAS HEATER

BLUE-FLAME MBP20LB

Note:

 Only mark last hole on each end of

mounting bracket. Insert mounting screws
through these holes only.

3.

Remove tape and mounting bracket
from wall.

INSTALLING HEATER TO
WALL

Mounting Bracket

The mounting bracket is located in the car-
ton. Remove mounting bracket from carton.

Figure 5 - Mounting Bracket

Removing Front Panel Of Heater

1.

Remove two screws near bottom cor-
ners of front panel.

2.

Lift straight up on grill guard until it
stops. Grill guard will slide up about
1/4".

3.

Pull bottom of front panel forward, then
down.

4.

Remove cardboard packing from grill
and glass.

Figure 6 - Removing Front Panel Of Heater

INSTALLATION

Continued

Methods For Attaching
Mounting Bracket To Wall

Only use last hole on each end of mounting
bracket to attach bracket to wall. These two
holes are 16 inches apart from their centers.
Attach mounting bracket to wall in one of
two ways.

1. Attaching to wall stud

2. Attaching to wall anchor

Attaching to Wall Stud:

 This method pro-

vides the strongest hold. Insert mounting
screws through mounting bracket and into
wall studs.

Attaching to Wall Anchor:

 This method

allows you to attach mounting bracket to
hollow walls (wall areas between studs) or
to solid walls (concrete or masonry).

Decide which method better suits your needs.
Either method will provide a secure hold for
the mounting bracket.

 WARNING: Maintain minimum

clearances shown in Figure 7. If
you can, provide greater clear-
ances from floor and joining wall.

Marking Screw Locations

1.

Tape mounting bracket to wall where
heater will be located. Make sure
mounting bracket is level.

2.

Mark screw locations on wall (see Fig-
ure 7).

Figure 7 - Mounting Bracket Clearances

16"

18 3/4"

Min.

7 1/4"

Min.

Adjoining Wall

Only Insert Mounting 

Screws Through Last 

Hole On Each End

Floor

Mounting Bracket

Содержание MBP20LB

Страница 1: ...uali fied installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinst...

Страница 2: ...sh outside air ven tilation to run properly This heater has an oxygen depletion sensor ODS pi lot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Com...

Страница 3: ...o light heater UNPACKING 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform deale...

Страница 4: ...h a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied...

Страница 5: ...appliances in the space Vent free heater ______________________ Btu Hr Gas water heater ______________________ Btu Hr Gas furnace ______________________ Btu Hr Vented gas heater _____________________...

Страница 6: ...willactivatethepowervent WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces VENTILATION...

Страница 7: ...ATER This heater is designed to be mounted on a wall Continued WARNING Maintain the mini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ancesfromfloor ceiling andjoin ing wall You can locat...

Страница 8: ...acket to wall These two holes are 16 inches apart from their centers Attach mounting bracket to wall in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This...

Страница 9: ...y For thick walls over 1 2 thick or solid walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bra...

Страница 10: ...Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur INSTALLATION Continued 3 Minimum Tee Joint Reduc...

Страница 11: ...es form ing show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5...

Страница 12: ...ure 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 8 Turn control knob counterclockwise to the...

Страница 13: ...re cleaning CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service pe...

Страница 14: ...ctionlooseatcon trol valve 5 Pilotflamenottouchingthermocouple which allows thermocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure...

Страница 15: ...e 1 When heated vapors from furniture polish was carpet cleaners etc turn into white powder residue REMEDY 1 Contactlocalpropane LPgascompany 2 Clean burner see Cleaning and Main tenance page 13 or re...

Страница 16: ...artially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Not enoug...

Страница 17: ...ane LP Only Ignition Piezo Pressure Regulator Setting 8 W C Inlet Gas Pressure inches of water Maximum 14 Minimum 11 Dimensions Inches H x W x D Heater 23 5 x 18 5 x 8 0 Carton 26 x 20 5 x 9 63 Weight...

Страница 18: ...18 105736 VENT FREE PROPANE LP GAS HEATER BLUE FLAME MBP20LB ODS PILOT 12 1 12 2 1 2 3 4 5 6 8 8 9 10 10 11 12 13 14 17 19 25 21 23 24 7 22 27 26 20 16 18 15 ILLUSTRATED PARTS BREAKDOWN MBP20LB...

Страница 19: ...able 1 11 098249 01 Nut M5 2 12 103594 04 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 106842 01 Ignitor Electrode 1 13 103446 01 Burner 1 14 099387 05 3 16 Pilot Tubing 1 15 103845 05 Inje...

Страница 20: ...nished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack...

Отзывы: