1.

STOP! Read the safety information
above.

2.

Make sure equipment shutoff valve
is fully open.

3.

Turn control knob clockwise 

Clockwise

to the OFF position.

LIGHTING

INSTRUCTIONS

  CAUTION: Do not try to ad-

just heating levels by using the
equipment shutoff valve.

OFF

HIGH

PILOT

LOW

IGNITOR

Ignitor Button

Control Knob

Figure 16 - Control Knob In The OFF
Position

Thermocouple

Pilot Burner

Ignitor Electrode

Figure 17 - Pilot

Shutting Off Heater

1.

Turn control knob clockwise 
to the PILOT position.

2.

Press in control knob and turn clock-
wise 

 to the OFF position.

3.

Turn off all electric power to the ap-
pliance if service is to be performed.

Shutting Off Burner Only (pilot
stays lit)

Turn control knob clockwise 

 to

the PILOT position.

TO TURN OFF GAS

TO APPLIANCE

4.

Wait five (5) minutes to clear out any
gas. Then smell for gas, including
near the floor. If you smell gas,
STOP! Follow “B” in the safety in-
formation, column 1. If you don’t
smell gas, go to the next step.

5.

Press in control knob and turn coun-
terclockwise 

 to the PILOT

position. Keep control knob pressed
in for five (5) seconds (see Figure 16).

Note:

 You may be running this

heater for the first time after hook-
ing up to gas supply. If so, the con-
trol knob may need to be pressed in
for 30 seconds. This will allow air to
bleed from the gas system.
• If control knob does not pop up when

released, contact a qualified service
person or gas supplier for repairs.

6.

With control knob pressed in, push
down and release ignitor button. This
will light pilot. The pilot is attached
to the front of burner. The burner
and pilot are located behind the heat
shield. If needed, keep pressing igni-
tor button until pilot lights.

Note: 

If pilot does not stay lit, refer

to Troubleshooting, pages 14 through
16. Also contact a qualified service
person or gas supplier for repairs.
Until repairs are made, light pilot
with match. To light pilot with match,
see Manual Lighting Procedure
.

7.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.

Note:

 If pilot goes out, repeat steps

3 through 7.

8.

Turn control knob counterclockwise

 to the LOW position. The

main burner should light. Set control
knob to any heat level between HIGH
and LOW. To turn control knob from
LOW to a higher setting, press in the
control knob and turn counterclock-
wise 

.

Note:

 both HIGH and LOW are

locked positions. You must press in
control knob before turning it from
these positions.

MANUAL LIGHTING

PROCEDURE

1.

Remove front panel (see Figure 6,
page 8).

2.

Follow steps 1 through 5 under Light-
ing Instructions
.

3.

With control knob pressed in, strike
match. Hold match to pilot until pi-
lot lights.

4.

Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Follow
step 8 under Lighting Instructions
.

5.

Replace front panel.

OPERATING
HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

A. This appliance has a pilot which must

be lighted by hand. When lighting the
pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all

around the appliance area for gas. Be
sure to smell next to the floor because
some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL
GAS
• Do not try to light any appliance.
• Do not touch any electric switch;

do not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow
the gas supplier’s instructions.

• If you cannot reach your gas sup-

plier, call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn
by hand, don’t try to repair it, call a
qualified service technician or gas
supplier. Force or attempted repair
may result in a fire or explosion.

D. Do not use this appliance if any part

has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part
of the control system and any gas con-
trol which has been under water.

  WARNING: If you do not fol-

low these instructions exactly, a
fire or explosion may result caus-
ing property damage, personal
injury or loss of life.

Содержание MBP20LB

Страница 1: ...uali fied installer service agency or the gas supplier WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manualforcorrectinst...

Страница 2: ...sh outside air ven tilation to run properly This heater has an oxygen depletion sensor ODS pi lot light safety system The ODS shuts down the heater if not enough fresh air is available See Air for Com...

Страница 3: ...o light heater UNPACKING 1 Remove heater from carton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform deale...

Страница 4: ...h a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on openable windows and doors and c caulking or sealants are applied...

Страница 5: ...appliances in the space Vent free heater ______________________ Btu Hr Gas water heater ______________________ Btu Hr Gas furnace ______________________ Btu Hr Vented gas heater _____________________...

Страница 6: ...willactivatethepowervent WARNING Rework work sheet adding the space of the adjoining unconfined space The combined spaces must have enough fresh air to supply all appliances in both spaces VENTILATION...

Страница 7: ...ATER This heater is designed to be mounted on a wall Continued WARNING Maintain the mini mumclearancesshowninFigure 4 Ifyoucan providegreaterclear ancesfromfloor ceiling andjoin ing wall You can locat...

Страница 8: ...acket to wall These two holes are 16 inches apart from their centers Attach mounting bracket to wall in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This...

Страница 9: ...y For thick walls over 1 2 thick or solid walls do not pop open wings 5 Place mounting bracket onto wall Line up last hole on each end of bracket with wall anchors 6 Insert mounting screws through bra...

Страница 10: ...Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to heater If pipe is too small undue loss of pressure will occur INSTALLATION Continued 3 Minimum Tee Joint Reduc...

Страница 11: ...es form ing show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5...

Страница 12: ...ure 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 8 Turn control knob counterclockwise to the...

Страница 13: ...re cleaning CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater before each use Have heaterinspectedyearlybyaquali fied service pe...

Страница 14: ...ctionlooseatcon trol valve 5 Pilotflamenottouchingthermocouple which allows thermocouple to cool causing pilot flame to go out This problemcouldbecausedbyoneorboth of the following A Low gas pressure...

Страница 15: ...e 1 When heated vapors from furniture polish was carpet cleaners etc turn into white powder residue REMEDY 1 Contactlocalpropane LPgascompany 2 Clean burner see Cleaning and Main tenance page 13 or re...

Страница 16: ...artially clogged 1 Gas leak See Warning statement at top of page 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Not enoug...

Страница 17: ...ane LP Only Ignition Piezo Pressure Regulator Setting 8 W C Inlet Gas Pressure inches of water Maximum 14 Minimum 11 Dimensions Inches H x W x D Heater 23 5 x 18 5 x 8 0 Carton 26 x 20 5 x 9 63 Weight...

Страница 18: ...18 105736 VENT FREE PROPANE LP GAS HEATER BLUE FLAME MBP20LB ODS PILOT 12 1 12 2 1 2 3 4 5 6 8 8 9 10 10 11 12 13 14 17 19 25 21 23 24 7 22 27 26 20 16 18 15 ILLUSTRATED PARTS BREAKDOWN MBP20LB...

Страница 19: ...able 1 11 098249 01 Nut M5 2 12 103594 04 ODS Pilot Assembly 1 12 1 098514 01 Thermocouple 1 12 2 106842 01 Ignitor Electrode 1 13 103446 01 Burner 1 14 099387 05 3 16 Pilot Tubing 1 15 103845 05 Inje...

Страница 20: ...nished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack...

Отзывы: