www.tensmachineuk.com                                                                                  Telephone: 0161 429 7330 

ELECTRODE INSTRUCTIONS

Turn Stimulator OFF before applying or removing electrodes

Application

1. Skin site must be very clean and dry. Dirty, flaky or oily skin will prevent electrodes from adhering to

the skin. If necessary, trim excess hair with scissors. If skin is oily wipe down with an alcohol or
electrode skin prep prior to application. Be sure to wash hands before handling electrodes.

2. Remove electrodes from bag and reseal bag to protect remaining electrodes.

3. Grasping a tiny edge of the electrode, peel and remove electrode from the protective plastic liner.

Save liner for electrode storage.

4. Place electrode onto skin treatment site (as recommended by your clinician) by firmly applying from

the centre of the electrode to the outer edges. Adhesion improves when electrodes reach skin
temperature.

5. If gel appears oversaturated with excessive moisture or perspiration, allow the electrode to air-dry

in a refrigerator with the gel side facing up until the gel regains its tack. If the gel appears dry, try
adding a few drops of water to the gel and allow to rest in a dust-free environment until the gel
regains its tack.

Removal and storage

1. Lift a corner of the electrode and slowly peel the electrode off the skin, touching the adhesive gel as

little as possible.

2. Place the electrodes back onto the saved protective plastic liner.

3. While grasping the electrodes connector with one hand, use the other hand to gently twist and

disconnect the lead wire pin from the electrode connector. .

4. Return the electrodes back into the storage bag and reseal tightly to prevent dry-out.

5. Store at room or cool temperature and keep out of direct sunlight.

6. The life of the electrode varies depending on skin conditions, amount of use, storage and climate.

Electrode life may be extended by carefully following the application, removal, and storage
instructions.

Caution

1. DO NOT place electrodes on broken skin. If skin irritation develops discontinue use. Consult

physician. Replace electrodes when they do not adhere or when treatment becomes uncomfortable.

2. DO NOT use unit while driving or operating machinery

3. DO NOT wear electrodes when showering, bathing or swimming

4. DO NOT apply electrodes across the head or across  the heart or on the front of your neck.

5. Keep electrodes separated during treatment

6. Using stimulation electrodes that are small or incorrectly applied could result in discomfort or skin

burns.

Содержание Comfy EMS Plus

Страница 1: ...se read this User Manual before using your Device Tel 0161 429 7330 www tensmachineuk com email sales thetenscompany co uk The Quick and Easy User Guide for the Maxi Stim EMS Plus Neuromuscular Stimul...

Страница 2: ...ompany registration number 08758741 Vat registration number 308286105 Thank you for purchasing a Med Fit Maxi EMS Plus Stimulator This device is manufactured to the highest of medical standards using...

Страница 3: ...STEP GUIDE 4 MUSCLE STIMULATOR PROGRAMMES 7 MANUAL ADJUSTMENTS 8 INTRODUCTION 11 HOW EMS WORKS 11 CAUTIONS 12 CONTRAINDICATIONS 12 ADVERSE REACTIONS 12 WARNINGS 13 ELECTRDOE INSTRUCTIONS 15 EMS PROGRA...

Страница 4: ...mpartment at the rear of the device This easy to use instruction manual explains how to set up the Med Fit Maxi Stim EMS Plus in programme mode Battery compartment Belt clip Fig A STEP BY STEP GUIDE 4...

Страница 5: ...nge the programme simply press the up down keys to the desired programme To access the controls open the front cover opens from the left hand side see Fig B for control functions Easy to use 2 channel...

Страница 6: ...ts as shown in Fig C Depending on the condition and treatment area you may use any number of electrodes up to a maximum of 4 electrodes and 2 channels Increase the intensity to the desired level pleas...

Страница 7: ...engthening Muscle Re Education Programmes Choose from one fo the programmes 5 6 7 and 8 Suitable Conditions These programmes can be used for building stamina and strength Muscle re eduction Please fol...

Страница 8: ...ernate The stimulation of CH2 will occur after the 1st contraction of CH1is completed In this mode the setting of the ON Time should be no less than two times of the Ramp time The Off Time should be E...

Страница 9: ...uld be selected for muscle strengthening and muscle bulk 50 120Hz pulse per second This range of frequency is used for strengthening re education and spasticity Using higher frequencies 50Hz plus requ...

Страница 10: ...ually 2 4 seconds ramp up time and 1 2 seconds ramp down time For a stronger stimulation increase ramp up time to maximum 8 seconds Stimulation modes Continuous mode device runs continually Synchronou...

Страница 11: ...ings This is being widely used in hospitals and sports clinics for the treatment of muscular injuries and for the re education of paralyzed muscles to prevent atrophy in affected muscles and improving...

Страница 12: ...lectrical conductive medium The irritation can usually be reduced by using an alternate conductive medium or alternate electrode placement 6 Electrode placement and stimulation settings should be base...

Страница 13: ...y to the carotid sinus reflex 3 Stimulation should not be applied over the neck or mouth Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to clo...

Страница 14: ...ent acid may leak from used batteries and damage the device Put the device and accessories in carrying box and keep it in cool dry place 6 The packed TENS EMS device should be stored and transported u...

Страница 15: ...ree environment until the gel regains its tack Removal and storage 1 Lift a corner of the electrode and slowly peel the electrode off the skin touching the adhesive gel as little as possible 2 Place t...

Страница 16: ...ec sec min 1 Muscle Training Re Education SYNCHRONOUS 30 300 0 1 1 30 2 Muscle Training Re Education SYNCHRONOUS 30 300 1 5 2 30 3 Muscle Training Re Education SYNCHRONOUS 30 300 1 10 3 30 4 Muscle Tr...

Страница 17: ...t areas of the body We are definitely not trying to give an anatomy class here but is is necessary to understand the whole muscle system to get a more precise grasp of the human muscle system The musc...

Страница 18: ...18 www tensmachineuk com Telephone 0161 429 7330 ELECTRODE PLACEMENT Forearm Biceps...

Страница 19: ...for muscle training and for gaining volume using the devices muscle strengthening programmes But it is equally very useful for diminishing the effects of lactic acid substances manufactured by the mus...

Страница 20: ...20 Telephone 0161 429 7330 www tensmachineuk com ELECTRODE PLACEMENT Internal Thigh Thigh...

Страница 21: ...21 www tensmachineuk com Telephone 0161 429 7330 The Gluteals This position is ideal for shaping the gluteal muscle ELECTRODE PLACEMENT The Trapezius muscles and Dorsals...

Страница 22: ...22 Telephone 0161 429 7330 www tensmachineuk com ELECTRODE PLACEMENT The Legs and Calves The medial and lateral gastrocnemius...

Страница 23: ...Telephone 0161 429 7330 The Abdominals It is the abdominal muscle which when electro stimulated will make a six pack appear ELECTRODE PLACEMENT The Pectorals BE SURE to follow the positioning DO NOT P...

Страница 24: ...s Mode Stimulation of both channels occurs synchronously The ON time including Ramp Up and Ramp Down time Therefore the setting of ON Time should be no less than two times of the Ramp time in this mod...

Страница 25: ...ality should be IEC 61000 4 5 line s mode that of a typical commercial or hospital environment Voltage dips 5 UT 5 UT Mains power quality should be short 95 dip in UT 95 dip in UT that of a typical co...

Страница 26: ...xed RF transmitters as determined by an electromagnetic site survey ashould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with...

Страница 27: ...ording to frequency of transmitter output power of m transmitter W 150 KHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 117 0 117 0 233 0 1 0 369 0 369 0 738 1 1 167 1 167 2 333 10 3 689 3 68...

Страница 28: ...Tel 0161 429 7330 Fax 0161 427 0215 www tensmachineuk com...