2

 

WARNING:

 

Qualified and specialized 

personnel. 

The device must be used 

exclusively by specialized and appropriately 

trained personnel such as a licensed dentist 

completely familiar with the required 

techniques and instructions for use of the 

equipment. The use of the device does not 

cause side effects if it is used correctly. An 

improper use might cause tissues heating.

 

WARNING:

 Use the device only for the 

intended use.  

Failure to observe this precaution may cause 

serious injuries to the patient, the operator, 

and damages/breakdowns to the device.

1.2 

Description of the Device

The PIEZOSURGERY® GP is a device that 

uses ultrasonic piezoelectric technology to 

generate mechanical microvibrations of the 

inserts,  to  effectively  cut  mineralized  tissues. 

This allows an efficient and safe cutting which 

preserves the integrity of the osteotomized 

surfaces.

The micrometric, ultrasonic vibrations of 

the inserts provide greater precision and 

a selective cutting action compared to 

traditional methods such as drills or oscillating 

saws  (which  act  with  macrovibrations), 

therefore  minimizing traumatic effect on soft 

tissues.

The cavitation effect of the irrigating solution 

helps to keep the operatory field blood-free. 

This  provides  an  optimal  intra-operatory 

visual control thus increasing safety, even in 

areas  that  are  anatomically  most  difficult  to 

access.

1.2.1  Users

U.S. Federal law restricts this device to sale by or on the order of a licensed dentist.

1.3 

Disclaimer

The manufacturer Mectron and the distributor, Piezosurgery Inc. disclaim any liability, expressed 

or implied, and shall have no responsibility for any direct, indirect or other damages and 

personal injury arising out in connection with any improper practice in the use of the device and 

its accessories. The manufacturer Mectron and the distributor, Piezosurgery Inc. shall be under 

no liability, expressed or implied, with respect to any damages (personal injury and/or damage 

to property) which might arise or be caused, whether by the customer or by any of the users of 

the product and its accessories, as result of:
 1. 

Use or procedures different than those 

specified in the intended use of the 

product;

 2.  The environmental conditions for the 

preservation and storage of the device 

are not compliant to the precautions  

indicated in the 

Chapter 8 on page 

25;

 3.  The device is not used in compliance 

with all the instructions and precautions 

described in this manual;

 4.  The electrical system in the premises 

in which the device is used is not 

compliant to the norms in force and to 

the relative precautions;

 5. 

The assembly operations, extensions, 

adjustments, updates, and repairs on 

the device are performed by personnel 

not authorized by Piezosurgery Inc.;

  6.  Improper use, mistreatments, and/or 

incorrect interventions;

  7. 

Any and all attempts to tamper with 

or modify the device, under any 

circumstance;

  8.  Use of non-original Piezosurgery/

Mectron inserts that entail a finite 

damage to the threading of the 

handpiece, thus compromising correct 

Содержание PIEZOSURGERY GP

Страница 1: ...USE AND MAINTENANCE MANUAL Rx Only CAUTION U S Federal law restricts this device to sale by or on the order of a licensed dentist 0051...

Страница 2: ...E A K H G B J F C I O M A D L N NOT SUPPLIED...

Страница 3: ...Piezosurgery GP is manufactured and sold internationally by Mectron S p A under the name Piezosurgery white P Q R S...

Страница 4: ......

Страница 5: ...I Copyright Mectron S p A 2021 All rights reserved No part of this document can be reproduced in any form without the written consent of the copyright owner...

Страница 6: ...ntenance 24 7 Disposal Method and Precautions 24 8 Technical Specifications 25 8 1 Electromagnetic Compatibility IEC EN 60601 1 2 26 8 1 1 Guidance and Manufacturer s Declaration Electromagnetic Emiss...

Страница 7: ...III PAGE INTENTIONALLY LEFT BLANK...

Страница 8: ...IV PAGE INTENTIONALLY LEFT BLANK...

Страница 9: ...this manual are updated as of the date of publication specified on the last page The manufacturer MECTRON S p A is committed to the continuous updating of its products which may entail changes to comp...

Страница 10: ...device to sale by or on the order of a licensed dentist 1 3 Disclaimer The manufacturer Mectron and the distributor Piezosurgery Inc disclaim any liability expressed or implied and shall have no respo...

Страница 11: ...anual is one year WARNING Checking device status before the treatment Always check that there is no water underneath the device Before every treatment always check that the device works perfectly and...

Страница 12: ...for single use only WARNING Only use original Piezosurgery Mectron inserts accessories and spare parts WARNING Contraindications Do not use the PIEZOSURGERY GP on patients who carry heart stimulators...

Страница 13: ...t Number Product Number Single Use Do not re sterilize Use by date Sterilized with Ethylene Oxide EO Non sterile Can be sterilized in autoclave up to a maximum temperature of 135 C Type B applied part...

Страница 14: ...d IP22 International Protection Code of the mechanical casing IP20 International Protection Code of the mechanical casing QTY 1 Quantity of items in the package 1 Rx Only For US market only CAUTION U...

Страница 15: ...GERY white 100 240 V 120 VA 50 60 Hz Rx Only 0051 00000000 YYYY MM DD made in Italy HIBC 128 Bar Code A separate label shows further symbols and characteristics of the device This identification label...

Страница 16: ...51 YYYY MM white Figure 1 Handpiece Identification Data 2 3 Inserts Identification Data The following data are laser marked on each insert the name of the insert Ref 1 the Mectron logo Ref 2 and the l...

Страница 17: ...sed for example kits and or dedicated torque wrenches Always read and follow the assembly and cleaning instructions supplied with the insert PIEZOSURGERY GP consists of accessories that can be ordered...

Страница 18: ...nt to the norms in force and to the relative electrical safety precautions CAUTION Only connect the console to hospital grade receptacles to ensure electrical grounding reliability This device must be...

Страница 19: ...der can be placed in 4 different positions right side front right side front left side and left side 2 Insert the peristaltic pump tubing supplied with the device into the connector of the handpiece c...

Страница 20: ...erate the footswitch of the PIEZOSURGERY GP device when the peristaltic pump cover is open Moving parts could injure the operator 6 Connect the peristaltic pump tubing to the flow adjuster not supplie...

Страница 21: ...tacle on the back of the console Connect it only to hospital grade receptacles 10 Equipotentialplug Thedeviceisequipped with an additional equipotential plug located on the rear of the console This pl...

Страница 22: ...and it is ready to use Switching the Device Off To switch the device off set the switch buttonlocatedontheleftsideofthedevice to position 0 taking care not to press the foot pedal down during this st...

Страница 23: ...d to the cutting and removal of highly mineralized bone IMPLANT dedicated to bone perforation in the technique of the implant site preparation FILLING AND FLUSHING THE IRRIGATION CIRCUIT Ref Q front e...

Страница 24: ...e irrigation column 7 capacity levels are available 0 no operation of the pump no irrigation outflows from the insert Da 1 a 6 the pump flow ranges from 8 ml min to approximately 75 ml min The irrigat...

Страница 25: ...onal PIEZOSURGERY GP is compatible with the PIEZOSURGERY touch handpiece only available as optional By connecting the PIEZOSURGERY touch handpiece the LED light on the front terminal of the handpiece...

Страница 26: ...ontact Piezosurgery Inc if the abnormalities concern the device CAUTION FLUSH function After the device is used with aggressive and non aggressive solutions it is necessary to perform a flushing cycle...

Страница 27: ...s the user must pay particular attention to avoiding injury from inserts with sharp points and cutting edges WARNING Breakage and wear out of the inserts High frequency oscillations and wear out may i...

Страница 28: ...ecting the irrigation kit from the physiological irrigation bag 1 To fill the irrigation circuit use the PUMP function To activate the FLUSH function press and hold the button PUMP FLUSH on the touch...

Страница 29: ...e handpiece firmly CAUTION The handpiece must not be grabbed by its terminal part and or cord but only by its central body The handpiece must not be rotated but must be grasped firmly and you must onl...

Страница 30: ...urgery Mectron insert NOTE Check the level of physiological solution contained in the irrigation bag Replace the irrigation bag with a new one before it is completely empty 7 After each use of PIEZOSU...

Страница 31: ...he warranty damages the threading of the PIEZOSURGERY GP handpiece with the risk of no longer being able to screw the original inserts correctly during subsequent use Moreover the device settings are...

Страница 32: ...ition If damaged replace it with an original Piezosurgery Mectron spare part 7 DISPOSAL METHOD AND PRECAUTIONS WARNING Hospital waste Treat the following items as hospital waste Inserts when they are...

Страница 33: ...ELLOUS CORTICAL IMPLANT Peristaltic pump capacity Adjustable on the touch screen ENDO PERIO 7 flow levels from 0 to 6 from 0 to approximately 75ml min SPECIAL CANCELLOUS CORTICAL IMPLANT 6 flow levels...

Страница 34: ...evice requires specific EMC precautions and must be installed and commissioned according to the EMC information provided in this chapter WARNING Only use original Piezosurgery Mectron accessories and...

Страница 35: ...ENT physiological signal simulation if used and the PIEZOSURGERY GP shall be located within 0 1 m of the vertical plane of the uniform field area in one orientation of the PIEZOSURGERY GP b PIEZOSURGE...

Страница 36: ...induced by RF fields c d o IEC 61000 4 6 3 V m 0 15 MHz 80 MHz 6 V m in the ISM bands between 0 15 MHz and 80 MHz n 80 AM at 1 KHz e Portable and mobile RF communication devices should not be used ne...

Страница 37: ...o line s k Not applicable to CLASS II PIEZOSURGERY GP l Direct coupling shall be used m r m s before modulation is applied n The ISM industrial scientific and medical bands between 0 15 MHz and 80 MHz...

Страница 38: ...amp is not suitable an EM clamp shall be used No intentional decoupling device shall be used between the injection point and the PATIENT COUPLING POINT in any case Testing may be performed at other mo...

Страница 39: ...to output lines intended to connect directly to outdoor cables b SIP SOPS whose maximum cable length is less than 3 m in length are excluded c Testing may be performed at other modulation frequencies...

Страница 40: ...400 Pulse modulation b 18 Hz 1 8 0 3 27 450 430 470 GMRS 460 FRS 460 FM c 5 kHz deviation 1 kHz sine 2 0 3 28 710 704 787 LTE band 13 17 Pulse modulation b 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 80...

Страница 41: ...c circuit that allows to detect operating abnormalities and to view their type on the keyboard via their relative symbol By using the following chart the user is guided toward the identification and p...

Страница 42: ...re turning it on again Abnormalities in the power distribution network excessive electrostatic discharges or internal anomalies Turn the device off and wait 5 seconds before turning it on again If the...

Страница 43: ...e socket Correctly insert the foot pedal plug into the socket on the back of the device The foot pedal is not working properly Contact Piezosurgery Inc s Service The device is switched on but not work...

Страница 44: ...Open the air inlet on the irrigation set The silicon tubing are incorrectly installed Check the irrigation kit connections The device is working properly but the pump works with difficulty Excessive...

Страница 45: ...electrical power socket before proceeding Apply leverage with a flat screwdriver inserting its tip in the seat of the fuse holder drawer located under the power supply socket 1 Pull out the fuse hold...

Страница 46: ...n authorization number that a quote is required If a quote is not requested the repair will be processed and your account billed accordingly provided the repair is not covered under warranty 9 4 2 Ret...

Страница 47: ...apter 9 4 on page 38 Returns must be authorized by PIEZOSURGERY Inc PIEZOSURGERY Inc cannot accept responsibility for returns which have not been authorized ContactPIEZOSURGERY Inc CustomerService at...

Страница 48: ...Revendeur Revendedor Manufacturer Mectron S p A Via Loreto 15 A 16042 Carasco Ge Italy Tel 39 0185 35361 Fax 39 0185 351374 www mectron com e mail mectron mectron com Distributed in U S by 850 Michiga...

Отзывы: