MPCIB 396 P6
mect s.r.l.
ME3025_13 03/21
28
Table 11
n
seq.
Press
key
appears
on
display
NOTE
1
prog.
PASS
Press the “prog.
” key to get into the
programming menu
2
prog.
0 0000 Input the personal Password number if already
programmed see “password Function”
** (confirm with “prog.
”)
3
OUtPUt
4
prog.
ALL
5
OUt.An
6
prog.
SEL.OA ANALOGUE OUTPUT SELECTION
7
prog.
E0.10
E0.10 = voltage output 0
10 V
C0.20 = current output 0
20 mA
C4.20 = current output 4
20 mA
Select the requested item with “
“ key and confirm
with “prog.
” key
8
SEL.OA
9
IS
BEGINNING OF READING SCALE
10
prog.
0 00000 write the reading value which coincides with ISO **
(confirm with “prog.
”)
11
IS
12
FS
END OF READING SCALE
13
prog.
1 00000 write the reading value which coincides with FSO **
(confirm with “prog.
”)
14
FS
15
ISO
BEGINNING OF ANALOGUE OUTPUT SCALE
16
prog.
000.00 write the output value which coincides with the
reading programmed in “IS”.
** (confirm with “prog.
”)
17
ISO
18
FSO
END OF ANALOGUE OUTPUT SCALE
19
prog.
010.00 write the output value which coincides with the
programmed reading at “FS”. ** (confirm with
“prog
.”)
20
FSO
21
Exit
Reset
Read out Procedure for exiting programming area