N seq. Key to
press
Appears
on the
display
NOTES
Press “
” key till when the desired function
appears on the display. Press “prog.
” to confirm
13
Reset
Exit
Readout To get out from the menu
2.5 “CoEnC” FUNCTION (encoder counting)
The “CoEnC” function gives you the possibility to get readings with major
resolutions using as much as possible the encoder resources.
Infact the bi-directional encoder produces two waves dephased of 90
. The reading
of an edge every four allows to visualize the encoder revolution pulses: this function
is obtained with the set up of “CoEnC” = F1 (fig.C). By the “CoEn” set up it is
possible to read two or four
edges
, getting double or quadruple readings about the
encoder revolution pulses. To double the reading you have to set up “CoEnC” = F2
(fig. B), while to quadruple you have to set up “CoEnC” = F4 (fig. A). See Table 4 to
set up this function.
Figure A
Figure B
Figure C