background image

NEED HELP? 1-800-832-2966

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 
Before using this generator and if you have any questions regarding the hazard and safety notices listed in this manual and/or on this generator, 
call 1-800-832-2966, Monday - Friday, 9 AM - 6 PM Central Time. 

 

 

 

Carbon Monoxide Gas:

 

When in operation, the exhaust from this generator contains poisonous carbon monoxide gas.  Carbon monoxide gas is both 

odorless and colorless and may be present even if you do not see or smell gas.  Breathing this poison gas can lead to headaches, dizziness, 
drowsiness, loss of consciousness and eventually death.

 

Use this generator ONLY outdoors in non-confined areas. 
Keep at least several feet of clearance on all sides to allow for proper ventilation for this generator. 

 

Powerful Voltage: 

This generator produces powerful voltage, which can result in electrocution. 

Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a bui lding electrical system to 
this generator without a qualified electrician completing the installation. 

Doing so voids your warranty. 

Such connections must isolate generator 

power from utility power and comply with local electrical laws and codes. Failure to comply can create a back feed into utili ty lines creating an 
electrocution hazard, which may result in serious injury or death. Such a back feed may cause this generator to explode, burn, and create fires when 
utility power is restored. 

Do not use this generator in wet conditions (rain, snow, active sprinkler systems, wet hands, etc.). Always keep this generator dry and operate it with dry 
hands. 
Do not touch bare wires or outlets (receptacles). 
Do not allow children or non-qualified persons to operate this generator. 

 

 

High Temperatures:

 This generator produces heat when in operation.  Temperatures near the exhaust can exceed 150° Fahrenheit (65° Celsius). 

Do not touch hot surfaces.  Observe all warning placards on this generator denoting hot surfaces. 
Allow this generator to cool for several minutes after use before touching the engine, muffler, or other areas that are hot during operation and before storing or 
transporting the generator. 
Hot exhaust may ignite some materials.  Keep flammable materials away from this generator. 
Keep several feet of clearance on all sides of this generator during operation.  Do not enclose this generator in any structure. 

 

 

Usage: 

Avoid the use of extension cords if possible. 

If you choose to use them, be sure they are sized adequately to handle the flow of 

electricity. An undersized cord can overheat, short out and cause a fire. 

 

Usage: 

Consult a physician(s) before using this generator if using a pacemaker. 

Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine, or when using the recoil starter. 

 

Usage: 

Misuse of this generator can damage it or shorten its life. 

 

Use this generator only for its intended purpose. 

 

Operate this generator only on a dry, level surface. 

 

Allow this generator to run for several minutes before connecting any electrical devices. 

 

Promptly turn off any malfunctioning devices and disconnect them. 

 

Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator.  

 

Do not turn on electrical devices until 

after they are connected to this generator. 

 

Turn off all connected electrical devices before stopping this generator. 

 

 

Usage: 

Prolonged exposure to high noise levels can be hazardous to hearing. 

Always wear ANSI-approved hearing protection when operating or 

working around the generator when it is running. 

 

Содержание MM2350

Страница 1: ...and situation that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT D...

Страница 2: ...smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO CALIFORNIA PROPOSITION 65 WARNING This product or the exhaust from this product may...

Страница 3: ...el Rating 69 dB Run time 9hrs 50 load Gasoline Power Outlets 1 12V DC Outlet 2 120V Outlets Model MM4350 DF This unit is a Gasoline or Gasoline Propane Dual Fuel powered generator FEATURES 4000 Surge...

Страница 4: ...oad Gasoline 8350 Run Time 11hrs 50 load Gasoline 9350 Power Outlets 1 12V DC Outlet 4 120V Outlets 1 120V RV Outlet 1 120 240V Outlet For all MECH MARVELS Generators in this Manual Recommended Fuel t...

Страница 5: ...his Generator for the First Time 14 STARTING THE GENERATOR 17 STARTING THE GENERATOR USING PROPANE 17 Switching from Gasoline to Propane 17 Switching from Propane to Gasoline 17 Subsequent Use of this...

Страница 6: ...uation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a...

Страница 7: ...ns to operate this generator High Temperatures This generator produces heat when in operation Temperatures near the exhaust can exceed 150 Fahrenheit 65 Celsius Do not touch hot surfaces Observe all w...

Страница 8: ...phones sparks from these sources can trigger an explosion or fire It can collect in low areas or travel along the ground where an ignition source may be present Pressure can also build up in the conta...

Страница 9: ...NEED HELP 1 800 832 2966 9 In addition to the previously described safety information familiarize yourself with all safety and hazard notices on this generator...

Страница 10: ...are missing items call 1 800 832 2966 Monday Friday 9 AM 6 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for charging 12 Volt...

Страница 11: ...Tank 7 Control Panel 8 Choke Used to start the engine 9 Air Filter Protects the engine by filtering dust and debris from the intake air 1 Recoil Starter Used to start the engine 2 Low Oil Shutdown Se...

Страница 12: ...40VAC Twist Lock Outlet 6 12V DC Connector 120VAC Duplex outlets are protected by 20A Circuit Breakers Each Duplex Outlet supports up to 2400 Watts 120VAC RV Outlet is protected by 30A Circuit Breaker...

Страница 13: ...e of the wheels by inserting the axle bolt and sliding a bushing in place 5 Carefully lift the rear of the generator and slide the assembly into the frame bracket Secure the axle bolt with the include...

Страница 14: ...oil in the engine crankcase Add the correct quantity of oil before operating this generator for the first time When replenishing oil for subsequent use of this generator always ensure that this genera...

Страница 15: ...ep 3 Ground the Generator Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3 Number 6 AWG American Wire Gauge stranded copper wire is generally a...

Страница 16: ...rtain the CHOKE VALVE is at CHOKE CLOSED position The generator may be hard to start if CHOKE VALVE is at the RUN OPEN position Step 3 Ensure engine oil is full Step 4 Make sure GROUND TERMINAL is pro...

Страница 17: ...connect any electrical devices to the generator prior to starting the engine 1 Make sure the fuel valve is in the OFF position 2 Make certain the propane hose is properly connected to the generator 3...

Страница 18: ...generator AC Usage Electrical devices running on AC current may be connected according to their wattage requirements The rated running and surge wattage Model MM2350 DF Rated Running Surge Wattage 12...

Страница 19: ...d by multiplying the Voltage requirement 120 or 240 by the Amperage drawn Watts Volts x Amperes Or the wattage required by a device can be estimated by using the following chart see Figure 8 The chart...

Страница 20: ...nto this generator NOTE While this generator is running power is available from either the standard 120 Volt outlets or the 12 Volt DC outlet Both 120 Volts and 12V can be simultaneously drawn from th...

Страница 21: ...lug end of the wire to the 12V DC outlet on this generator 3 Start this generator 4 When disconnecting turn off the generator and always disconnect the wires from this generator first to avoid the ris...

Страница 22: ...commended Maintenance Schedule Each Use Every Month or Each 20 Hrs Every 3 Months or Each 50 Hrs Every 6 Months or Each 100 Hrs Every Year or Each 300 Hrs Engine Oil Check Level X Change X First Use X...

Страница 23: ...the pan and transfer to a container for recycling 4 Remove the oil fill cap dipstick 5 Re install the drain plug 6 Refill with the recommended oil and check the oil level 7 Wash your hands with soap...

Страница 24: ...after seating to compress the washer If re installing the original plug it will typically require less 8 Re attach the plug wire to the plug Torch Spark Plug Type Spark Plug Gap NGK Spark Plug Type E...

Страница 25: ...drain bolt and drain the gasoline into a suitable container by the fuel drain pipe c When all the fuel is drained tum the petcock to the OFF position and tighten the drain screw securely 3 Change the...

Страница 26: ...ESHOOTING Be sure that there is no fuel spilled around the spark plug spilled fuel may ignite Does not spark Consult authorized service center Consult authorized service center Check the Spark Plug Se...

Страница 27: ...RV 1 12VDC 8A 1 12VDC 8A Net Gross Weight 51 60Lbs 51 5 62Lbs 94 8 103 6lbs 95 2 105 4lbs Noise Level 69dB 69dB 70dB 70dB Unleaded Gasoline Unleaded Gasoline Unleaded Gasoline Unleaded Gasoline LPG 20...

Страница 28: ...A 1 120 240VAC 30A 1 12VDC 8A 1 12VDC 8A 1 12VDC 8A Net Gross Weight 196 0 204 8lbs 202 8 211 6lbs 204 8 213 6lbs Noise Level 73dB 73dB 73dB Unleaded Gasoline Unleaded Gasoline Unleaded Gasoline LPG 2...

Страница 29: ...America Inc will repair or replace at its discretion any part that is proven to be defective in materials or workmanship under normal use during the 1 YEAR warranty period Warranty repairs or replace...

Страница 30: ...is warranted for the warranty period stated above Any such part repaired or replaced under warranty will be warranted for the remaining warranty period 3 Any warranted part that is scheduled for repl...

Страница 31: ...ipe manifold b Air cleaner 3 Ignition system including a Spark plug b Ignition coil 4 Catalytic muffler assembly including a Muffler gasket b Exhaust manifold c Catalytic converter if available 5 Cran...

Отзывы: