Page 17
92RT Scssor Lfts - Operator’s Manual
July 2020
Secton 6 - Functon Tests and Operatng Instructons
Do not elevate platform unless guardrails are installed and secure – see
Fold Down Platform Railings on page 22�����
If the deck is extended, check for clearance beneath the deck before
lowering�����
If the platform fails to lower DO NOT attempt to climb down the scissor
assembly����� Serious injury may result – see Emergency Systems on page
20�����
ART_2386 R2
Elevate Platform
Place the Mode Select Switch in the LIFT position.
Squeeze the Enable Bar and move the Joystick toward you.
Test Operation
Rate of lift is proportional and is dependent on the movement of the
Joystick.
Elevate to maximum height.
Note
Platform will not elevate beyond 30 ft. (9.15 m) without the outriggers
deployed
Releasing the Enable Bar or the Joystick will stop elevation.
Pressing the Emergency Stop Switch will stop elevation.
Lower Platform
Place the Mode Select Switch in the LIFT position.
Squeeze the Enable Bar and move the Joystick toward you.
Test Operation
Rate of descent is fixed - platform lowers at same rate regardless of
handle position.
Pressing the Emergency Stop Switch will stop descent.
•
•
•
•
•
•
•
•
•
•
Check that the route is clear of persons, obstructions, debris, holes and
drop -offs, and is capable if supporting the machine�����
IMPORTANT
Always check front steer wheel direction before driving.