Page 101
45-J Desel - Servce & Parts Manual
January 2022
Secton 19 - Troubleshootng
To Serial #14700199
Art_5583
Adjustments & Setups
BOOM 45JD
EZ-CAL MENU
HELP
PRESS ENTER
1
DIAGNOSTICS
2
ACCESS LEVEL
3
ADJUSTMENTS
4
SETUPS
5
ENTER
ERROR
MESSAGE
ENTER
LOGGED
MESSAGES
PRESS RT & LT
ARROWS TO VIEW
PREVIOUS
ERRORS &
MESSAGES
ENTER
SYSTEM
2A
FUNCTIONS
2B
DIGITALS
2C
ANALOGS
2D
OUTPUTS
2E
SEE
CHART
# 2
ACCESS LEVEL
2
FOR
CALIBRATIONS
ACCESS LEVEL
1
FOR
ADJUSTMENTS
ENTER
LOG
2F
CW MIN
40%
4E-1
CW MAX
57%
4E-2
CCW MIN
39%
4E-3
CCW MAX
56%
4E-4
ACCEL
2.0 SEC
4E-5
DECEL
0.6%
4E-6
DRIVE
4A
RISER
NOT USED
4C
TELESCOPE
4D
SWING
4E
JIB
4F
PLATFORM
4G
TILT
4H
OVERLOAD
(CE ONLY)
4J
GROUND
MODE
4L
UP MIN
15%
4C-1
UP MAX
45%
4C-2
DOWN MIN
15%
4C-3
DOWN MAX
32%
4C-4
ACCEL
1.5 SEC
4C-7
DECEL
0.5 SEC
4C-8
FWD MIN
13%
4A-1
FWD MAX
35%
4A-2
4A-3
REV MIN
12%
4A-4
REV MAX
35%
4A-5
4A-6
ACCEL
3.0 SEC
4A-7
ACCEL
1.5 SEC
4A-10A
DECEL
1.5 SEC
4A-10B
ENTER
ENTER
FWD MIN
12%
4A-9A
FWD MID
0%
4A-9B
FWD MAX
20%
4A-9C
REV MIN
12%
4A-9D
REV MID
0%
4A-9E
REV MAX
22%
4A-9F
OUT MIN
23%
4D-1
OUT MAX
47%
4D-2
IN MIN
26%
4D-4
IN MAX
56%
4D-5
4D-6
ACCEL
1.5 SEC
4D-8
UP MIN
32%
4F-1
UP MAX
53%
4F-2
DOWN MIN
37%
4F-4
DOWN MAX
63%
4F-5
*CW MIN
0%
4F-7
*CW MAX
0%
4F-8
* UP MIN
14%
4G-1
* UP MAX
23%
4G-2
*
DOWN MIN
12%
4G-3
4G-4
*L TO P UP
1.7
4G-5
*L TO P DOWN
1.7
4G-6
CW MAX
37%
4G-9
CCW MIN
35%
4G-10
X TRIP
5.0°
4H-1
Y TRIP
5.0°
4H-2
DELAY TRIP
1.5 SEC
4H-3
DELAY CLEAR
0.5 SEC
4H-4
TRIP @
105%**
4J-1
LAMP @
0%
4J-2
ALARM @
0%
4J-3
@ HEIGHT
0%
4J-5
SAFE DOWN
9%
4J-6
DELAY TRIP
1.5 SEC
4J-7
SPEED
55%
4L-1
DELAY CLEAR
1.5 SEC
4J-8
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
CCW MAX
43%
4G-11
*L TO P STEP
20
4G-7
CW MIN
32%
4G-8
ENTER
ENTER
CHANGE
DEFAULTS
5A
TILT
SETUPS
5B
HEIGHT
SETUPS
5D
LOAD
SETUPS##
5E
INTERLOCKS
5F
5B-1
5B-2
5B-3
5D-1
ELEVATION @
10%
5D-2
5D-3
TRANSPORT @
101%
5D-4
5D-5
5A-1
MODEL
4= 45J ANSI
5= 45J CE
5A-2
CUSTOMER
6= 45J
5F-2
E TIME OUT
10.0 SEC
5F-3
WAIT FOR GO
0.2 SEC
5F-3
PUMP DELAY
0.2 SEC
5F-4
5E-1
CALIBRATE
LOAD
SEE
INSTRUCTION
5E-3
5E-4
DYNAMIC
SCALE
110%
5 SEC
ENTER
ENTER
ENTER
ENTER
ENTER
5D-6
5E-2
CELLS
0
SETTINGS AND
ADJUSTMENTS
MUST NOT BE
CHANGE WITHOUT
PRIOR
AUTHORIZATION
FROM
MEC AERIALS
TEMPERATURE
5G
5G-1
FAN ON
65 DEG C
ENTER
STARTER DELAY
10 SEC
5F-5
TILT FILTER
4
4H-5
** SET TO 0 FOR
MODELS NOT
EQUIPPED WITH
OVERLOAD SENSING
OPTION
AXLE @
0%
TILT CORRECTION
1= X+
CALIBRATE HEIGHT
SEE INSTRUCTIONS
5D-7
MAX LIFT
97%
MAX DRIVE
101%
THROTTLE HOLD
FWD MAXHIGH
55%
REV MAXHIGH
55%
DECEL
2.2 SEC
4A-8
DRIVE ELEVATED
4A-9
STR MIN
50%
4A-10C
STR MAX
50 %
4A-10D
PUMP MAX
80%
4A-12
PUMP MIN
35%
4A-13
DECEL
0.7 SEC
4D-9
W/LIFT
47%
ACCEL
0.5 SEC
4F-11
DECEL
0.5 SEC
4F-12
*CCW MIN
0%
4F-9
*CCW MAX
0%
4F-10
*DOWN MAX
21%
ALARMS
4M
TILT
1:WHEN ELEV
4M-1
MAKE
SELECTION
FROM MENU
4M-2
ENTER
ACCEL
0.5 SEC
4G-12
DECEL
0.5 SEC
4G-13
FAULTY LOAD
-100%
CALIBRATE
LEVEL SEE
INSTRUCTION
TILT
SHUTDOWN
0= NEVER
ELEVATED
TILT
SHUTDOWN
0=NEVER
GENERATOR
5H
GEN LOW
66.0 VOLTS
5H-1
ENTER
5G-2
FAN OFF
45 DEG C
GEN HIGH
93.0 VOLTS
5H-2
SETTINGS AND
ADJUSTMENTS
MUST NOT BE
CHANGE WITHOUT
PRIOR
AUTHORIZATION
FROM MEC
AERIALS
## LOAD
SETUPS &
OVERLOAD
USED ON
MACHINES
WITH
OVERLOAD
SENSING
OPTION ONLY
W/LIFT
49%
4D-3
RET IN MAX
33%
4D-7
MAXSLOW
40%
4F-3
MAXSLOW
40%
4F-6
AUX UP
MAX
55%
4L-2
AUX DOWN
MAX
30%
4L-3
5F-1
ENABLE
4A-11
BRAKE DELAY
0.5 SEC
FAN AND
GENERATOR
SETTINGS
NOT USED
ON I/C
POWERED
UNITS
AXLE ANGLE
0-ANSI / 0-CE
4H-6
5D-8
SLOW DOWN
5%
EXTEND @
0%
4J-4
1=MUL
ACCEL
2.0 SEC
4A-9G
DECEL
1.0 SEC
4A-9H
LIFT
4B
UP MIN
15%
4B-1
UP MAX
44%
4B-2
DOWN MIN
16%
4B-3
DOWN MAX
40%
4B-4
ACCEL
1.5 SEC
4B-5
DECEL
0.71 SEC
4B-6
ENTER
DRIVE STEER
4A-10
END
SCALE UP
30%
4C-5
END SCALE
DOWN
30%
4C-6
AUTO GLOW
10 SEC
5F-6
80
4D-10
!PWM CORR
IN RPM
HIGH
4D-10A
ENTER
*NOT
USED
PPSS
4K
#SENSORS
2%
4K-1
CLOSE@
40%
4K-2
FAR@
80%
4K-3
145%
4K-4
SHUTDOWN@
ENTER
ENGINE
5J
SYMBOL
KEY FUNCTIONS
EZ-Cal Flow Chart
Chart 1 of 2
ESC/ENTER BUTTONS
To move back and forth between
Menu and sub-menu
LEFT/RIGHT BUTTONS
Select menus and setting to be adjusted
UP/DOWN BUTTONS
Adjust setting values
ENTER
5J-1
5J-2
5J-3
RPM MIDDLE
900
RPM
THROTTLED
1800
TELE IN
RPM
HIGH
5G-3
HYD TEMP
50 DEG F
GEN RMS
0.0 VOLTS
5H-3
GEN RPM
0=NORMAL
5H-4
GEN MAX
100%
5H-5
P5-10 UP
33%
4B-7
P5-10DOWN
33%
4B-8
P5-10 OUT
33%
4D-11
P5-10IN
33%
4D-12
* YOUR
PLATFORM
LEVEL
SETTINGS
MAY DIFFER
FROM LISTED
SETTINGS. IF
YOUR
PLATFORM
LEVELING
OPERATES
CORRECTLY,
DO NOT
CHANGE
THEM
Содержание 45-J Diesel
Страница 1: ...Service Parts Manual Part 95090 January 2022 Serial Number Range 14700001 Up 45 J Diesel Art 5500...
Страница 31: ...Page 25 45 J Diesel Service Parts Manual January 2022 Section 10 Hydraulic System Art_5706 ILLUSTRATION No...
Страница 132: ...Page 126 45 J Diesel Service Parts Manual January 2022 Notes...
Страница 195: ...Page 189 45 J Diesel Service Parts Manual January 2022 Section 25 Hydraulics THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 229: ...Page 223 45 J Diesel Service Parts Manual January 2022 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 243: ...Page 237 45 J Diesel Service Parts Manual January 2022 Section 27 Options THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 257: ...Page 251 45 J Diesel Service Parts Manual January 2022 Notes...