PSE
.
12
.
USER Submenu:
USER
Sub-
Menu1
Sub-
Menu2
Option
Remark
Setting
RESET
NO
NO
Reset user parameters to factory setting
NO
YES
COM1
BAUD.RT
1200
Selection of com1's
baud rate
9600
2400
4800
9600
19200
38400
BYT.FMT
8N1
Selection of com1's byte format:
8N1
=8 data bits, No parity check bit, 1 stop bit;
7O1
=7 data bits, 1 Odd parity check bit, 1 stop bit;
7E1
=7 data bits, 1 Even parity check bit, 1 stop bit;
7O2
=7 data bits, 1 Odd parity check bit, 2 stop bit;
7E2
=7 data bits, 1 Even parity check bit, 2 stop bit;
8N1
7O1
7E1
7O2
7E2
OUT.MOD
NONE
Selection com1 output mode:
NONE
=No communication;
CONT
=continuously output;
=output after PRINT key pressed;
CMD
=output after a request command is received;
PRT.CMD
= output after PRINT key pressed or request
command received;
STABLE
=output after scale is stable;
Note:
use PRINT or CMD to output data, the scale must be
stable.
CONT
CONT
CMD
PRTCMD
STABLE
LAYOUT
MULTPL
Com1 output content and format set:
MULTPL
= the following selected item in OUT1 will be output
use defined format;
SINGLE
= only displayed content and current status will be
output, it¡s compatible with NCI-SCP01;
EH-SCP
= Command ¨ response mode;
SCP-12
= only displayed content and current status will be
output, it¡s compatible with NCI-SCP12(NCI3835);
SINGLE
SINGLE
EH-SCP
SCP-12
OUT1
SCAL.ID
YES
Yes/No
=enable/disable output scale's ID number, Prompt is
¡ SCALE ID¡
NO
NO
GROSS
YES
Yes/No
=enable/disable output gross weight. Prompt is
¡ GROSS¡
NO
NO
TARE
YES
Yes/No
=enable/disable output tare weight. Prompt is ¡ TARE¡
NO
NO
NET
YES
Yes/No
=enable/disable output net weight. Prompt is ¡ NET¡
YES
NO
PERCNT
YES
Yes/No
=enable/disable output weight percentage. Prompt is
¡ PERCENTAGE¡
NO
NO