PSE
.
9
.
SubMenu1
SubMenu2
Option
Remark
Setting
PRIM.Ut
KG
Select the primary unit from kg or lb; defaulted
calibration standard weight unit is the primary unit.
LB
LB
SECND.N
100-
125000
The division number under second unit, the max is
1.25*(PRIM.N).
10,000
3000
10N.DSP
NO
Display weight at 10 times division number under
primary unit.
if (REGULAR)=none, this item will not be shown
no
YES
MOTION
1-255
Check motion window:
1-255
=¡ 0.25d *(1-255),
4
OVER.LD
0-100
Over load display limitation:
0
=FS+9d;
1-100
=101%FS -200%FS,
0
AD.FROM
ADC
Data of ADC comes from:
ADC
=local A/D chip on PCB;
COM3
=COM3 interface;
ADC
COM3
AD.H.SPD
NO
Speed of A/D convert:
NO
=10Hz;
YES
=80Hz;
if AD.FROM=COM3,this item will not be shown
NO
YES
UNITS
KG
YES
Units that can be used by UNIT key select:
YES
=enable this unit to be used;
NO
=disable this unit to be used;
Refer to table5-1 and table5-2.
For legal-for-trade application, lb:oz is not allowed.
YES
NO
LB
YES
YES
NO
OZ
YES
NO
NO
LB OZ
YES
no
NO
G
YES
NO
NO
ZRO.PNT
IZSM
0-100
Initial zero(power on zero) point range:
0
=no limitation;
1-100
= (calibration zero point) ¡ 1%FS ~(calibration
10
10
IN.IZSM
WEIGHT
Choose which weight as current initial zero point when
current weight is in IZSM range:
WEIGHT
= current weight ;
CAL.ZRO
= calibration zero;
LAST.Z.T
=switch-off zero and tare
If
N.A
(
WEIGHT
)
CAL.ZRO
LAST.Z.T