7
2
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
PACKING
OVERLOAD
Note.4
OVER VOLTAGE
Note.4
BATTERY CUTOFF
AC CURRENT (Typ.)
Protection type : Shut down o/p voltage, re-power on to removed
-20 ~ +60
(Refer to "Derating Curve")
℃
20 ~ 95% RH non-condensing
±
℃
℃
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
1.02Kg; 12pcs/13.5Kg/0.78CUFT
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5 & 6)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
℃
OUTPUT NUMBER
225*124*41mm (L*W*H)
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Conducted
Radiated
Harmonic Current
Voltage Flicker
Standard
Standard
BS EN/EN55032 (CISPR32),
EAC TP TC 020
BS EN/EN55032 (CISPR32),
EAC TP TC 020
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-4
BS EN/EN61000-4-5
BS EN/EN61000-4-6
BS EN/EN61000-4-8
Test Level / Note
Test Level / Note
Class A
Class A
-----
-----
-----
-----
1019.6K hrs min.
Telcordia SR-332 (Bellcore);
144.4K hrs min.
MIL-HDBK-217F (25
)
?
FUNCTION
CHARGER CIRCUIT FAIL
AC OK
2000ms, 50ms/230VAC
2000ms, 50ms/115VAC at full load
47 ~ 63Hz
90%
91%
12A/115VAC
7.5A/230VAC
COLD START 35A/115VAC
60A/230VAC
<0.5mA Peak / 240VAC
CH1:105 ~ 135%
CH2:90 ~ 110%
21.5V 0.5V
±
32V 0.5V
±
CH1:31 ~ 36V
CH1:47 ~ 55V
LAD-600BU
LAD-600CU
27.6V
CH2
41.5V
CH2
27.6V
CH1
41.5V
CH1
3A(Battery Charger)
3A(Battery Charger)
18.74A
11.45A
0 ~ 21.74A
0 ~ 14.45A
600.02W
599.67W
--------
--------
270mVp-p
360mVp-p
CH1: 21.6 ~ 29V
CH1: 32.4 ~ 43.5V
--------
--------
--------
--------
--------
--------
±
1.0%
±
1.0%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
90 ~ 132VAC / 180 ~ 264VAC by switch
240 ~ 370VDC
(Default switch at 230VAC)
16ms/230VAC
12ms/115VAC at full load
91%
43V 0.5V
±
CH1:59 ~ 69V
LAD-600DU
55 2V
.
CH2
55 2V
.
CH1
3A(Battery Charger)
7.87A
0 ~ 10.87A
600.02W
--------
360mVp-p
CH1: 43 5 ~ 58V
.
--------
--------
--------
±
1.0%
±
0.5%
±
0.5%
BATTERY STATIC DISCHARGE
CURRENT
<100μA
OVER TEMPERATURE
Note.4
BATTERY REVERSE POLARITY
Level 3, 8KV air ; Level 2, 6KV contact; criteria A
Level 3, 10V/m ; criteria A
Level 3, 2KV ; criteria A
Level 3, 1KV/Line-Line ;2KV/Line-FG ;criteria A
Level 3, 10V ; criteria A
Level 4, 30A/m ; criteria A
115VAC Input :
when input voltage <75VAC
Signals AC failure and activates
Recover the main power supply when input voltage >87VAC
230VAC Input :
when input voltage <165VAC
Signals AC failure and activates
Recover the main power supply when input voltage >175VAC
Protection type : Shut down o/p voltage, re-power on to removed
Battery
, battery reverse polarity signal failure
,
disconnected
BUZZER ALARM
Protection type : CH1 OLP, CH2 with battery: he unit will enter to UPS mode when CH1 is around 105%~120%,
T
when total output of CH1 + CH2 reach around 125%~135% output shuts down
CH1 OLP, CH2 without battery:Shut down o/p voltage,re-power on to removed
CH2 : Constant current limiting; fault condition does not affect CH1 working,recovers automatically after fault
condition is removed (External fuse is mandatory in series connection with battery for protection)
Protected when reverse polarity , no damage, recovers automatically after fault condition is removed
Battery low( fire alarm system selectable by UART)
AC fail, Battery low,
disconnected
selectable by
battery
, battery reverse connect, overload status (evacuation system
UART)
-30 ~ +85
, 10 ~ 95% RH non-condensing
℃
UL6
-1
2368 , BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved; Design refer to GB 17945-2010
GB4717
,
--------
--------
--------
LAD-600xU Series UART Communication Function Model(U Version)
8
2
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
PACKING
OVERLOAD
Note.4
OVER VOLTAGE
Note.4
BATTERY CUTOFF
AC CURRENT (Typ.)
-20 ~ +60
(Refer to "Derating Curve")
℃
20 ~ 95% RH non-condensing
±
℃
℃
0.03%/
(0 ~ 50
)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
1.02Kg; 12pcs/13.5Kg/0.78CUFT
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 5 & 6)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-FG:2KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
℃
OUTPUT NUMBER
225*124*41mm (L*W*H)
EMC IMMUNITY
EMC EMISSION
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Conducted
Radiated
Harmonic Current
Voltage Flicker
1154.4K hrs min.
Telcordia SR-332 (Bellcore);
169.9K hrs min.
MIL-HDBK-217F (25
)
?
2000ms, 50ms/230VAC
2000ms, 50ms/115VAC at full load
47 ~ 63Hz
90%
91%
12A/115VAC
7.5A/230VAC
COLD START 35A/115VAC
60A/230VAC
<0.5mA Peak / 240VAC
CH1:105 ~ 135%
CH2:90 ~ 110%
21.5V 0.5V
±
32V 0.5V
±
CH1:31 ~ 36V
CH1:47 ~ 55V
LAD-600B
LAD-600C
27.6V
CH2
41.5V
CH2
27.6V
CH1
41.5V
CH1
--------
--------
270mVp-p
360mVp-p
CH1: 21.6 ~ 29V
CH1: 32.4 ~ 43.5V
--------
--------
--------
--------
--------
--------
±
1.0%
±
1.0%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
90 ~ 132VAC / 180 ~ 264VAC by switch
240 ~ 370VDC
(Default switch at 230VAC)
16ms/230VAC
12ms/115VAC at full load
91%
43V 0.5V
±
CH1:59 ~ 69V
LAD-600D
55 2V
.
CH2
55 2V
.
CH1
--------
360mVp-p
Ch1: 43 5 ~ 58V
.
--------
--------
--------
±
1.0%
±
0.5%
±
0.5%
<100μA
BATTERY STATIC DISCHARGE
CURRENT
OVER TEMPERATURE
Note.4
Standard
Standard
BS EN/EN55032 (CISPR32),
EAC TP TC 020
BS EN/EN55032 (CISPR32),
EAC TP TC 020
BS EN/EN61000-4-2
BS EN/EN61000-4-3
BS EN/EN61000-4-4
BS EN/EN61000-4-5
BS EN/EN61000-4-6
BS EN/EN61000-4-8
-----
-----
Test Level / Note
Test Level / Note
Level 3, 8KV air ; Level 2, 6KV contact; criteria A
Level 3, 10V/m ; criteria A
Level 3, 2KV ; criteria A
Level 3, 1KV/Line-Line ; 2KV/Line-FG ;criteria A
Level 3, 10V ; criteria A
Level 4, 30A/m ; criteria A
Class A
Class A
-----
-----
OUTPUT
INPUT
MODEL
Protection type : Shut down o/p voltage, re-power on to removed
Protection type : Shut down o/p voltage, re-power on to removed
3A(Battery Charger)
3A(Battery Charger)
18.74A
11.45A
0 ~ 21.74A
0 ~ 14.45A
600.02W
599.67W
3A(Battery Charger)
7.87A
0 ~ 10.87A
600.02W
DISCHARGE
FUNCTION
TTL signal, High/Open :
; Low : Charge ; Ice : max. 30mA@ 50VDC
Discharge
AC OK
TTL signal, High/Open : AC OK ; Low : AC Fail ; Ice : max. 30mA@ 50VDC
BATTERY DISCONNECT/
REVERSE POLARITY
BATTERY LOW
TTL signal, High/Open :Battery
; Low : Battery
normal; Ice : max. 30mA@ 50VDC
disconnect/reverse polarity
connect/
TTL signal, High/Open : Battery low ; Low : Battery normal; Ice : max. 30mA@ 50VDC
BATTERY FULL
TTL signal, High/Open : Battery full ; Low : Battery charging ; Ice : max. 30mA@ 50VDC
UL62368-1,
approved;
BS EN/EN62368-1 AS/NZS62368.1,
,
Design refer to GB 17945-2010
EAC TP TC 004
-30 ~ +85
, 10 ~ 95% RH non-condensing
℃
Protection type : CH1 OLP, CH2 with battery: he unit will enter to UPS mode when CH1 is around 105%~120%,
T
when total output of CH1 + CH2 reach around 125%~135% output shuts down
CH1 OLP, CH2 without battery:Shut down o/p voltage,re-power on to removed
CH2 : Constant current limiting; fault condition does not affect CH1 working,recovers automatically after fault
condition is removed (External fuse is mandatory in series connection with battery for protection)
BATTERY REVERSE POLARITY
Protected when reverse polarity , no damage, recovers automatically after fault condition is removed
--------
--------
--------
LAD-600x Series TTL Communication Function Model(Blank Version)