Meaco MeacoMist Deluxe Скачать руководство пользователя страница 4

 

4

 

 

GENERAL ADVICE

 

 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

 

Before putting your humidifier into operation for the first time, the instruction manual should be 
studied carefully.  

 

After receiving the humidifier, you should check the unit for any transport damage. In case of 
damage, you should inform the sender immediately.  

 

The humidifier should be placed on a steady, flat surface. Do not place the humidifier close to 
any  heat  sources,  such  as  a  fireplace  or  stove.  Avoid  the  humidifier  being  placed  in  direct 
sunlight. 

 

 

Ensure the humidifier is placed away from any furniture or electronic appliances to avoid any 
damage via damp. 

 

 

Keep the packaging for the humidifier in a safe place in order to be able to despatch the unit 
safely if it requires a service. In order to save space, you can simply cut through the adhesive 
tape using a knife and fold the cardboard box.  

 

 

HUMIDIFIER PRINCIPLES

 

 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

High speed vibrations inside the humidifier create tiny water particles that are blown into the room from 
the top of the humidifier.  

We recommend setting the humidifier to reach a target level of 40%rh to 60%rh. Mould forms at 68%rh 
so it is important not to set the target humidity level too high.  

The ultraviolet lamp in the base of the humidifier when turned on will kill bacteria and germs that might 
be present in the water to ensure that the mist that is humidified is as clean as possible. As part of this 
process the plastic in the base will discolour and will turn yellow. This is not a fault and is impossible to 
prevent, it is proof that the UV is doing its job. The UV lamp turns off when the tank is removed from 
the base. Never try and look directly at an UV lamp when in use as it could damage your eyesight. 

It is very normal for an ultrasonic humidifier to create a puddle of water on whatever surface it is standing 
on. You can avoid or reduce this by directing the mist nozzles away from each other to ensure that the 
mist goes in different directions and it is not all concentrated in the one area. You can also reduce the 
mist output if necessary, to reduce the amount of moisture landing in front of the humidifier. A MeacoFan 
could also be used to help distribute the mist around the whole of your room. 

If the furniture that you are placing the humidifier is vulnerable to moisture damage, then we recommend 
using a different location or protecting the surface in front of the humidifier. 

 

 

 

 

 

 

 

Содержание MeacoMist Deluxe

Страница 1: ...idifier and Air Purifier Instruction Manual MeacoMist Deluxe Humidifier Please read this instruction manual before using the MeacoMist and keep safe for future reference Thank you for choosing Meaco we really appreciate it ...

Страница 2: ...ounded and able to deliver the appropriate voltages to the unit Handle with Care Do not drop throw or crash the unit Rough treatment can damage the components or wiring and create a hazardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the unit cannot fall and cause injury Keep Out of Water Never operate the un...

Страница 3: ...rminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or coloured GREEN or GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly 5 Only ever us...

Страница 4: ... so it is important not to set the target humidity level too high The ultraviolet lamp in the base of the humidifier when turned on will kill bacteria and germs that might be present in the water to ensure that the mist that is humidified is as clean as possible As part of this process the plastic in the base will discolour and will turn yellow This is not a fault and is impossible to prevent it i...

Страница 5: ... 2 Top cover 3 Cleaning brush 4 Water tank handle 5 Water tank 6 Water level window 7 Water tank cap 8 Water housing 9 Control panel 10 Air outlet 11 Base 12 HEPA filter 13 Filter cover 14 Legs 15 Aroma box 16 Power cord 17 Humidity Sensor ...

Страница 6: ...TOP COVER WATER TANK BASE UNDERNEATH Handle Mist nozzle Water tank cap Low water level sensor Temperature and humidity sensor PTC heater Ultrasonic pad Water tank sensor Air outlet Drain hole safety feature Aroma Box HEPA filter cover ...

Страница 7: ...BUTTON When the humidifier is first plugged in to the mains the machine will beep and turn on in Standby Mode Press the Power Button once the LED display will light up and the machine will start to work Press the Power Button again the machine will stop working and go back into Standby Mode AUTO MODE Press the Auto Night Button to enter the automatic control mode In this mode the machine will main...

Страница 8: ...utton down again for 3 seconds to turn the ioniser off WARM MIST Press the Warm Mist Button to start the warm mist function The PTC element in the machine will start working and the mist will become warm Three vertical lines will appear on the display to confirm that warm mist has been set Activating warm mist will increase the humidification output Press the Warm Mist Button again to stop this fu...

Страница 9: ...e top cover and water tank from the base 3 Turn the water tank upside down and unscrew the water tank cap removing it from the water tank The calcium carbonate filter will be attached to the water tank cap 4 Fill the water tank with water screw the water tank cap back in place and securely place the water tank back onto the base The water tank level can be viewed through the window on the left han...

Страница 10: ...box Put the aroma box back into the machine The aroma function will automatically work when the machine is turned on To stop the aroma function or when the machine is not in use for a long period of time remove the sponge from the aroma box and clean it Re insert the aroma box into the machine 9 Choose your desired setting using the control panel see pages 7 and 8 for more information 10 Please no...

Страница 11: ... 0 hours Press the power button again and the humidifier will run as per before ULTRASONIC PAD AND PTC HEATER The ultrasonic pad and PTC heater can be located in the base of the humidifier The ultrasonic pad vibrates at high speed in order to turn water into mist The PTC heater heats up the water when the warm mist option is chosen In areas where the water quality is hard limescale will form on th...

Страница 12: ...ipe the inside of the base using a damp cloth The inside of the base must be cleaned weekly Please note any yellowing of the plastic is normal and is caused by the UV lamp working correctly CALCUIM CARBONATE FILTER The calcium carbonate filter can be found inside the water tank attached to the water tank cap To regenerate the calcium carbonate filter sit the filter in water that is 5 salt for 24 h...

Страница 13: ...oal filter can be found underneath the base of the humidifier and must be replaced when the colour changes from white to dark grey this will roughly be every 6 months To remove the HEPA charcoal filter press the filter cover open Remove plastic wrapping from the replacement HEPA charcoal filter before installing The replacement HEPA charcoal filter must be inserted so the HEPA white side is facing...

Страница 14: ...ower 25W 105W Noise Level Maximum 35dB A Maximum 45dB A Aroma Diffuser Yes Ioniser Yes Ultraviolet Water Sterilisation Yes Timer Yes between 1 and 10 hours Night Mode Yes Adjustable Humidity Level Yes between 40 rh and 80 rh Auto Shut Off Yes HEPA Filter Yes Carbon Filter Yes Dimensions HWD 335 x 255 x 150 mm Nett Weight 2050g ...

Страница 15: ...e water is dirty Clean the water tank see page 12 and replace the water The machine is noisy The water tank is in the incorrect position Make sure the water tank is securely in place There is not enough water in the water tank Fill the water tank with more water see page 9 The machine is on an uneven surface Place the machine on a flat stable surface The HEPA charcoal filter is blocked Replace the...

Страница 16: ...d by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation including consequential damage will not be entertained 9 Using a third party switching device that turns the humidifier on or off via the mains will invalidat...

Страница 17: ...e harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...

Отзывы: