WARRANTY AND CUSTOMER SERVICE 

----------------------------------------------------------------------------------------------------------------------------- ----------

 

There  is  a  two-

year  manufacturer’s  warranty  on  your  humidifier  from  the  date  of  purchase.  Please 

register your purchase at 

https://meaco.com/warranty-register

 - as a thank you, you will be entered into 

our monthly free prize draw to help support the David Shepard Wildlife Foundation. Registering also 
allows us to keep you update with any important developments concerning your product.

 

Within the two-year manufa

cturer’s warranty, all manufacturing defects will be repaired free of charge 

(excluding damage caused by wear and tear, limescale, mineral deposits or dirt in the water). Filters 
are not covered under the manufacturer’s warranty. 

 

The following applies: 

1.  Any  repairs  or  replacement  of  components  during  the  warranty  period  will  not  result  in  an 

extension of the warranty period. 

2.  The warranty will expire if any alterations have been made, not genuine components have been 

fitted or if the humidifier has been repaired by a third party.  

3.  Components subject to normal wear and tear are not covered by the warranty. 

4.  The  warranty  is  only  valid  on  presentation  of  the  original,  unaltered,  and  date-stamped 

purchased receipt.  

5.  The warranty does not cover damage caused by actions that deviate from those as described 

in the user’s manual or by neglect.  

6.  The warranty does not cover faults caused by dirt or by third-party products. 

7.  The warranty does not cover accidental damage.  

8.  All claims for compensation, including consequential damage, will not be entertained.  

9.  Using  a  third-party  switching  device  that  turns  the  humidifier  on  or  off  via  the  mains  will 

invalidate the warranty.  

For the full list of the warranty terms and conditions please visit

www.meaco.com/warranty-terms

. 

To prevent unnecessary expenses, we recommend that you always carefully read the user’s manual 
first. If this does not provide a solution, please call Meaco and we will be happy to help.  

 

This humidifier has been imported into  
the UK by: 

 

Meaco (UK) Limited 
Meaco House 
Parklands 
Railton Road 
Guildford 
GU2 9JX 

 

Telephone: 01483 234900 
Email

[email protected]

  

Website: 

www.meaco.com

 

 

If your humidifier develops a fault at any time, please contact us and we will always try and help you as 
best we can. Please keep hold of the original box and packaging your unit arrived in just in case we 
need to collect the humidifier from you for a repair/service in the future.  

Please record, for future reference, your date of 
purchase and where you bought the humidifier from 
here. 

 

Date of purchase

…………………..…………………

 

Purchased from 

www.meaco.com

 (if not, then 

please record the supplier’s name below).

 

 

Suppliers name: 

……………………………………….

 

 

 

 

Serial number:……………………………………..

 

 

 

 

Содержание MeacoMist Deluxe

Страница 1: ...idifier and Air Purifier Instruction Manual MeacoMist Deluxe Humidifier Please read this instruction manual before using the MeacoMist and keep safe for future reference Thank you for choosing Meaco we really appreciate it ...

Страница 2: ...ounded and able to deliver the appropriate voltages to the unit Handle with Care Do not drop throw or crash the unit Rough treatment can damage the components or wiring and create a hazardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the unit cannot fall and cause injury Keep Out of Water Never operate the un...

Страница 3: ...rminal which is marked with the letter N or coloured BLACK 2 The BROWN wire is the LIVE and must be connected to the terminal which is marked with the letter L or coloured RED 3 The GREEN YELLOW is the EARTH and must be connected to the terminal which is marked with the letter E or coloured GREEN or GREEN YELLOW 4 Always ensure that the cord grip is positioned and fastened correctly 5 Only ever us...

Страница 4: ... so it is important not to set the target humidity level too high The ultraviolet lamp in the base of the humidifier when turned on will kill bacteria and germs that might be present in the water to ensure that the mist that is humidified is as clean as possible As part of this process the plastic in the base will discolour and will turn yellow This is not a fault and is impossible to prevent it i...

Страница 5: ... 2 Top cover 3 Cleaning brush 4 Water tank handle 5 Water tank 6 Water level window 7 Water tank cap 8 Water housing 9 Control panel 10 Air outlet 11 Base 12 HEPA filter 13 Filter cover 14 Legs 15 Aroma box 16 Power cord 17 Humidity Sensor ...

Страница 6: ...TOP COVER WATER TANK BASE UNDERNEATH Handle Mist nozzle Water tank cap Low water level sensor Temperature and humidity sensor PTC heater Ultrasonic pad Water tank sensor Air outlet Drain hole safety feature Aroma Box HEPA filter cover ...

Страница 7: ...BUTTON When the humidifier is first plugged in to the mains the machine will beep and turn on in Standby Mode Press the Power Button once the LED display will light up and the machine will start to work Press the Power Button again the machine will stop working and go back into Standby Mode AUTO MODE Press the Auto Night Button to enter the automatic control mode In this mode the machine will main...

Страница 8: ...utton down again for 3 seconds to turn the ioniser off WARM MIST Press the Warm Mist Button to start the warm mist function The PTC element in the machine will start working and the mist will become warm Three vertical lines will appear on the display to confirm that warm mist has been set Activating warm mist will increase the humidification output Press the Warm Mist Button again to stop this fu...

Страница 9: ...e top cover and water tank from the base 3 Turn the water tank upside down and unscrew the water tank cap removing it from the water tank The calcium carbonate filter will be attached to the water tank cap 4 Fill the water tank with water screw the water tank cap back in place and securely place the water tank back onto the base The water tank level can be viewed through the window on the left han...

Страница 10: ...box Put the aroma box back into the machine The aroma function will automatically work when the machine is turned on To stop the aroma function or when the machine is not in use for a long period of time remove the sponge from the aroma box and clean it Re insert the aroma box into the machine 9 Choose your desired setting using the control panel see pages 7 and 8 for more information 10 Please no...

Страница 11: ... 0 hours Press the power button again and the humidifier will run as per before ULTRASONIC PAD AND PTC HEATER The ultrasonic pad and PTC heater can be located in the base of the humidifier The ultrasonic pad vibrates at high speed in order to turn water into mist The PTC heater heats up the water when the warm mist option is chosen In areas where the water quality is hard limescale will form on th...

Страница 12: ...ipe the inside of the base using a damp cloth The inside of the base must be cleaned weekly Please note any yellowing of the plastic is normal and is caused by the UV lamp working correctly CALCUIM CARBONATE FILTER The calcium carbonate filter can be found inside the water tank attached to the water tank cap To regenerate the calcium carbonate filter sit the filter in water that is 5 salt for 24 h...

Страница 13: ...oal filter can be found underneath the base of the humidifier and must be replaced when the colour changes from white to dark grey this will roughly be every 6 months To remove the HEPA charcoal filter press the filter cover open Remove plastic wrapping from the replacement HEPA charcoal filter before installing The replacement HEPA charcoal filter must be inserted so the HEPA white side is facing...

Страница 14: ...ower 25W 105W Noise Level Maximum 35dB A Maximum 45dB A Aroma Diffuser Yes Ioniser Yes Ultraviolet Water Sterilisation Yes Timer Yes between 1 and 10 hours Night Mode Yes Adjustable Humidity Level Yes between 40 rh and 80 rh Auto Shut Off Yes HEPA Filter Yes Carbon Filter Yes Dimensions HWD 335 x 255 x 150 mm Nett Weight 2050g ...

Страница 15: ...e water is dirty Clean the water tank see page 12 and replace the water The machine is noisy The water tank is in the incorrect position Make sure the water tank is securely in place There is not enough water in the water tank Fill the water tank with more water see page 9 The machine is on an uneven surface Place the machine on a flat stable surface The HEPA charcoal filter is blocked Replace the...

Страница 16: ...d by actions that deviate from those as described in the user s manual or by neglect 6 The warranty does not cover faults caused by dirt or by third party products 7 The warranty does not cover accidental damage 8 All claims for compensation including consequential damage will not be entertained 9 Using a third party switching device that turns the humidifier on or off via the mains will invalidat...

Страница 17: ...e harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling ...

Отзывы: