background image

 

 

The MeacoDry Arete One dehumidifier uses the new R290 refrigerant gas to comply 
with European Environmental Directives. R290 is kinder to the environment and is part 
of attempts to reduce global warming as it has a low greenhouse effect (GWP). 

 
When using the MeacoDry Arete One you must take into account the following: 

 

This dehumidifier uses about 65 grams of R290 refrigerant, which is flammable. Therefore, it is 
part of a sealed system and must only be serviced by a trained Meaco engineer. 

 

Do not use or store this dehumidifier in a room smaller than 4m² to prevent a fire or explosion 
hazard if there is a leak of refrigerant and the gas comes into contact with an ignition source. 

 

Do not use in a room with any continuous sources of ignition, for example open flames, gas 
fires or hobs, cigarettes or any other sources of ignition. 

 

If the dehumidifier is installed, operated or stored in a non-ventilated area, then the room must 
be  designed  to  prevent  the  accumulation  of  refrigerant  leaks  resulting  in  a  risk  of  fire  or 
explosion due to ignition of the refrigerant caused by electric heaters, cookers, or other sources 
of ignition. 

 

R290 refrigerant gas is odourless. 

 

Do not puncture either during the units working life or after.  At the end of life dispose of following 
local recycling regulations. 

 

If there is any damage to the dehumidifier then do not use it and contact Meaco or your retailer.   

 

As with all dehumidifier, always keep upright and leave the dehumidifier standing upright for six 
hours before using it upon receipt. 

 

Failure to comply with these instructions could result in fire, damage to property, serious 
injury or potentially death. 

 

 
Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued 
by  a  national  accredited  organisation  that  ensures  competence  in  handling  flammable  refrigerants 
according  to  a  specific  evaluation  recognised  by  national  associations  in  the  industry  and  compliant 
with the latest R290 guidance. 

Servicing  should  only  be  carried  out  by  a  Meaco  approved  engineer  using  original  Meaco  parts  to 
prevent damage to the unit and potential injury to the engineer. 

 

 

 

 

 

 

 

 

 

Содержание MeacoDry Arete One

Страница 1: ...MeacoDry Arete One 20L and 25L Dehumidifier and Air Purifier Thank you for choosing Meaco we really appreciate it ...

Страница 2: ...r the appropriate voltages to the unit Handle with Care Do not drop throw or crash the dehumidifier Rough treatment can damage the components or wiring and create a hazardous condition Run on Stable Surface Always operate the unit on a stable level surface for example the floor or a strong counter so that the dehumidifier cannot fall and cause injury Keep Out of Water Never operate the unit in poo...

Страница 3: ...f refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric heaters cookers or other sources of ignition R290 refrigerant gas is odourless Do not puncture either during the units working life or after At the end of life dispose of following local recycling regulations If there is any damage to the dehumidifier then do not use it and contact Me...

Страница 4: ...have moved during transit to settle 4 Choose where you would like to locate your dehumidifier see page 5 for advice This dehumidifier has been carefully designed allowing you to place the dehumidifier as close to a wall as you wish 5 Insert the H13 HEPA filter that has been provided with your dehumidifier This will enable air purification as well as dehumidification For instructions on how to do t...

Страница 5: ... dehumidifier to reduce the humidity level in a single room or area of the house use the same settings as above however situate the dehumidifier inside the problem room or area and keep the internal door closed Using your dehumidifier to dry your laundry Dehumidifiers are very efficient at drying your laundry quickly and cheaply When doing so we would recommend the following Situate your dehumidif...

Страница 6: ...l a H13 HEPA filter and a right angle adaptor to enable continuous drainage Front view Side view Water Tank Air outlet Control panel Handle Water Tank Castors Cable Tidy Filter case and dust filter combined Handle To lift the handle use two hands one on the left and one on the right hand side then lift ...

Страница 7: ...we stopped providing hoses with our dehumidifiers to reduce the amount of plastic going to waste To make things easier for our customers who wish to use continuous drainage we have included an adaptor which fits a standard garden hose ID 12 5mm For more information on how to use continuous drainage see pages 12 and 13 Cable Tidy Filter case and dust filter combined Castors Handle ...

Страница 8: ...rh has been reached 3 rh the dehumidifier will stop Every 30 minutes the fan will run and check the humidity level the dehumidifying indicator will turn off If the humidity level has increased more than 3 above the target the compressor will turn on and the dehumidifier will start to run again the dehumidifying indicator will be solid If the humidity level is within 3 of the target the dehumidifie...

Страница 9: ...in high fan speed when the humidity level is 15 rh within the target the dehumidifier will be in low fan speed Air Purification Mode Hold the smart humidity button down for 2 seconds to enter air purification mode AP will show on the display In air purification mode the dehumidifier will not dehumidify it will simply purify the air This mode is useful during the summer months when dehumidification...

Страница 10: ...midifier off The dehumidifier will bleep once and the child lock indicator will light up To remove child lock hold the night mode child lock button down for another 2 seconds Dehumidifying Indicator The dehumidifying indicator will light up solid when the compressor is running and the dehumidifier is dehumidifying The indicator will turn off when the dehumidifier is checking the humidity level Wat...

Страница 11: ...sed to make it easier to carry the water tank Use the pouring holes on the left or right corner of the water tank to empty the water the water tank lid does not need to be removed The water collected can be used to water non edible plants only do not consume Cleaning the water tank If you want to clean the inside of the water tank the water tank lid needs to be removed simply lift the lid off the ...

Страница 12: ...ess this can take a couple of days or it could take 4 weeks it is individual for each situation If your dehumidifier does not collect lots of water to begin with it does not mean it is faulty it could mean your humidity level is already low or you need to change the settings If you have any questions feel free to call us on 0911 88080553 Continuous Drainage Hose not included For more information s...

Страница 13: ...ight angle adaptor from the water tank lid and push it onto the spout The spout is where water drips out of the dehumidifier and is located on the left hand side Step 3 Attach the hose to the spout Step 4 Insert the water tank back into the dehumidifier ...

Страница 14: ... for wear and tear reasons When used regularly the filter may become clogged with dust and dirt particles The filter must be cleaned a minimum of every two weeks not doing so could invalidate the units warranty Please follow the steps below 1 Remove the dust filter from the dehumidifier by sliding the filter case to the left away from the dehumidifier The dust filter is built into the filter case ...

Страница 15: ...can be hoovered every so often to remove any dust or dirt To insert replace the HEPA filter place it inside the combined filter case and dust filter then slide the combined filter case and dust filter into the dehumidifier Replacement HEPA filters can be purchased from eu meaco com Storage If the dehumidifier will not be used for a long period of time take the following steps 1 Remove the plug fro...

Страница 16: ... Low Fan Speed 145m h High Fan Speed 160m h Low Fan Speed 150m h High Fan Speed 175m h Auto restart Yes Yes Filter Type Dust Filter and optional HEPA filter Dust Filter and optional HEPA filter Power Supply 220 240V 50Hz 220 240V 50Hz Fan Speeds 2 automated depending on humidity level 2 automated depending on humidity level Operating Temperatures 5 to 35 C 5 to 35 C Refrigerant R290 65g R290 90g W...

Страница 17: ...ation E1 flashes every 30 seconds on the display Please contact Meaco E2 flashes every 30 seconds on the display Please contact Meaco L3 slowly flashes on the display The environment the dehumidifier is being used in is too warm Make sure the dehumidifier is being used in 40 C or less L4 slowly flashes on the display The environment the dehumidifier is being used in is too cold Make sure the dehum...

Страница 18: ...ide temperature has dropped and the windows are now colder Use the dehumidifier on a lower target setting and run it 24 hours a day The condensation on my windows will not go even when the dehumidifier is in CO mode The surface temperature of the windows is too low for a dehumidifier to prevent condensation This is common with single glazed windows and when the air temperature outside drops below ...

Страница 19: ... harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmentally safe recycling ...