MDV HM/II-130S Скачать руководство пользователя страница 8

Hydraulic Module 50Hz                                                                                                                                            MCAC-ATSM-2014-11

 

 

 

No. 

Part    Name 

Qty 

No. 

Part    Name 

Qty 

Middle support board 

19 

Base welded parts 

Rear panel 

20 

Column II 

Middle column 

21 

Handle 

The welded parts of top cover 

22 

Front panel II 

Column I 

23 

Soft rubber joint 

Y-shape filter 

24 

Front panel I 

Outlet water pipe ass'y of water tank 

25 

Outlet water pipe ass'y of water pump 

Pumping rod type brass gate valves 

26 

Safety valve 

Water pump return pipe ass'y 

27 

Support ass'y of total outlet water pipe 

10 

Outdoor unit electric control box ass'y 

28 

Support ass'y of expansion tank 

10.1 

Welded parts of electric control box   

29 

Water baffle II 

10.2 

Outdoor main control board ass'y 

30 

Connection pipe of expansion tank 

10.3 

AC contactor 

31 

Right side board 

10.4 

Transformer   

32 

Expansion tank 

10.5 

Seven Terminal Block 

33 

Inlet water pipe ass'y of water tank 

10.6 

Wire joint 

34 

Check valve 

10.7 

Terminal block 

35 

Welded parts of water tank 

11 

Left side board 

36 

Exhaust valve 

12 

Cover of electric control box 

37 

Target flow-volume controller 

13 

Pressure difference by-pass valve 

38 

Water charge valve 

14 

Water baffle I 

39 

Snap ring ass'y 

15 

Welded part of electric control box support 

40 

Total outlet water pipe ass'y 

16 

The belt of expansion tank 

41 

Compressor electric heater 

17 

Soft rubber joint 

43 

Cover of inlet/outlet pipe 

18 

Water pump 

 

 

 

Содержание HM/II-130S

Страница 1: ...Application range 4 7 Specifications 4 8 Dimensions 5 9 Wiring Diagram 6 10 Exploded views 7 11 Selection 11 12 Key components configuration parameter 11 13 Trouble shooting 12 14 Installation 13 Manu...

Страница 2: ...e control cabinet can achieve linkage control with any formal air condition mainframe through active or passive junction 2 4 Easy installation and maintenance The unit can be installed indoor or outdo...

Страница 3: ...motor safety class is IP24 insulation class is F 3 External appearance 4 Nomenclature HM V II 65 S Power Supply S 380V 50Hz 3Ph D 220V 60Hz 3Ph Rated cooling capacity kW Water pump quantity I one pum...

Страница 4: ...25 Power supply frequency 2 Three phase current imbalance 5 7 Specifications Content Unit HM II 65S HM II 130S Recommended cooling capacity corresponding to the range selection kW 65 130 Water flow m...

Страница 5: ...MCAC ATSM 2014 11 Hydraulic Module 50Hz 5 8 Dimensions Unit mm HM II 65S HM II 130S...

Страница 6: ...Hydraulic Module 50Hz MCAC ATSM 2014 11 6 9 Wiring Diagram HM II 65S HM II 130S...

Страница 7: ...MCAC ATSM 2014 11 Hydraulic Module 50Hz 7 10 Exploded views HM II 65S...

Страница 8: ...0 1 Welded parts of electric control box 1 29 Water baffle II 1 10 2 Outdoor main control board ass y 1 30 Connection pipe of expansion tank 1 10 3 AC contactor 2 31 Right side board 1 10 4 Transforme...

Страница 9: ...MCAC ATSM 2014 11 Hydraulic Module 50Hz 9 HM II 130S...

Страница 10: ...ectric control box 1 29 Water baffle II 1 10 2 Outdoor main control board ass y 1 30 Connection pipe of expansion tank 1 10 3 AC contactor 2 31 Right side board 1 10 4 Transformer 1 32 Expansion tank...

Страница 11: ...oor unit combined quantity and type 3 Each water system design of pump head please refer to flow head curve 12 Key components configuration parameter No Name Connection dimension Parameter 1 Fixed pre...

Страница 12: ...t by linkage and manual the coil voltage is normal Cut off power supply press on contactor by hand the contactor is broken if don t press down Replace contactor Relay failure Normally start pump by ma...

Страница 13: ...e orifice and water pipe joint respectively in order to avoid the module set water pipe be damaged by large torque result in water pipe cracking and leakage 3 In order to improve the efficiency of wat...

Страница 14: ...it it must change the by pass valve of pressure difference to the position displays in the figure 5 If the module operates at lower temperature environment or don t use it for a long time please add e...

Страница 15: ...liding 4 Pipe installation Provide pipe installation schematic drawing and the name of connection orifice should be shown at the position of waterpower module orifice convenient to connect system pipe...

Страница 16: ...dismantled Lifting should be done as the packing direction and added two guard plates in case of damage or deformation 4 When suspension module to moving please use the flexible sling in order to avoi...

Страница 17: ...it nameplates is the quantitative value under standard running conditions The selection of miniature circuit breaker AC contactor wiring capacity and so on has been considered while the module is oper...

Страница 18: ...s pipeline 14 8 Safety in use 1 Should close down immediately dump checkup and repair if find following conditions A Electrical machine current exceed 10 or above of rated current for a long time B Ma...

Отзывы: