1 Introduction 

The series hydraulic module is designed for air-cooled scroll chiller unit, it built-in two pumps, one is backup. The water pump can 

be automatic switching under failure (malfunction shifting).

 

It is the use of the hydraulic module integration solutions, is a 

completely prefabricated sets strict monitoring of products, with a pump, valve, automatic replenishment, safety components, 

bypass components, drain dirty sewage and control system, etc. For water cycle, constant pressure to supply water for all water 

media transportation, for industrial, commercial and residential buildings, it is the best choice for water distribution system. 

Capacity range: 

Applies to air-cooled scroll chiller from 65&130kW. 

2 Feature 

2.1 Backup function 

It built-in two pumps, one is backup. It can be automatically switched between two pumps in failure. 

2.2 High-class main components 

It adopts dustproof and waterproof designed for main components. For the pipe, it adopts brass, stainless steel or metal with 

special coating and anti-rust treatment. 

2.3 Intelligent control, energy security 

The control cabinet can achieve linkage control with any formal air-condition mainframe through active or passive junction. 

 

   

 

 

2.4 Easy installation and maintenance 

The unit can be installed indoor or 

outdoor, suit for different customer’s requirement. There are screw connecting and flange 

connecting, convenient for connecting. 

2.5 Save the installation space and cost.   

Integrated design, covering area is small. Intelligent control, it saves energy more than 30% than traditional. For air-cooled 

scroll 

chiller, it’s no need expansion tank.   

2.6 Fixed pressure replenishing water valve 

It consists of reducing valve, stop valve and check valve. The automatic replenishment valve consists reduced pressure and 

stable pressure device, the pressure value can be automatically adjusted and kept, which according to pressure gauge and the 

replenishment valve scale, when the system pressure is low, it will be automatically open to filling water, automatically close 

when the pressure up to setting value, avoid to damage system device cause of high pressure. 

Maximum pressure of inlet water

10 bar 

The pressure adjustment range

0.5

4 bar 

Water flow signal output 

Alarm signal output 

To  W1/W2  PORT  of  air  cooled 

scroll chiller 

Hydraulic 

  Module 

 

Power input 

380V 3Ph~50Hz 

Pump signal input 

Signal from P1/P2 port of 

air cooled scroll chiller   

Содержание HM/II-130S

Страница 1: ...Application range 4 7 Specifications 4 8 Dimensions 5 9 Wiring Diagram 6 10 Exploded views 7 11 Selection 11 12 Key components configuration parameter 11 13 Trouble shooting 12 14 Installation 13 Manu...

Страница 2: ...e control cabinet can achieve linkage control with any formal air condition mainframe through active or passive junction 2 4 Easy installation and maintenance The unit can be installed indoor or outdo...

Страница 3: ...motor safety class is IP24 insulation class is F 3 External appearance 4 Nomenclature HM V II 65 S Power Supply S 380V 50Hz 3Ph D 220V 60Hz 3Ph Rated cooling capacity kW Water pump quantity I one pum...

Страница 4: ...25 Power supply frequency 2 Three phase current imbalance 5 7 Specifications Content Unit HM II 65S HM II 130S Recommended cooling capacity corresponding to the range selection kW 65 130 Water flow m...

Страница 5: ...MCAC ATSM 2014 11 Hydraulic Module 50Hz 5 8 Dimensions Unit mm HM II 65S HM II 130S...

Страница 6: ...Hydraulic Module 50Hz MCAC ATSM 2014 11 6 9 Wiring Diagram HM II 65S HM II 130S...

Страница 7: ...MCAC ATSM 2014 11 Hydraulic Module 50Hz 7 10 Exploded views HM II 65S...

Страница 8: ...0 1 Welded parts of electric control box 1 29 Water baffle II 1 10 2 Outdoor main control board ass y 1 30 Connection pipe of expansion tank 1 10 3 AC contactor 2 31 Right side board 1 10 4 Transforme...

Страница 9: ...MCAC ATSM 2014 11 Hydraulic Module 50Hz 9 HM II 130S...

Страница 10: ...ectric control box 1 29 Water baffle II 1 10 2 Outdoor main control board ass y 1 30 Connection pipe of expansion tank 1 10 3 AC contactor 2 31 Right side board 1 10 4 Transformer 1 32 Expansion tank...

Страница 11: ...oor unit combined quantity and type 3 Each water system design of pump head please refer to flow head curve 12 Key components configuration parameter No Name Connection dimension Parameter 1 Fixed pre...

Страница 12: ...t by linkage and manual the coil voltage is normal Cut off power supply press on contactor by hand the contactor is broken if don t press down Replace contactor Relay failure Normally start pump by ma...

Страница 13: ...e orifice and water pipe joint respectively in order to avoid the module set water pipe be damaged by large torque result in water pipe cracking and leakage 3 In order to improve the efficiency of wat...

Страница 14: ...it it must change the by pass valve of pressure difference to the position displays in the figure 5 If the module operates at lower temperature environment or don t use it for a long time please add e...

Страница 15: ...liding 4 Pipe installation Provide pipe installation schematic drawing and the name of connection orifice should be shown at the position of waterpower module orifice convenient to connect system pipe...

Страница 16: ...dismantled Lifting should be done as the packing direction and added two guard plates in case of damage or deformation 4 When suspension module to moving please use the flexible sling in order to avoi...

Страница 17: ...it nameplates is the quantitative value under standard running conditions The selection of miniature circuit breaker AC contactor wiring capacity and so on has been considered while the module is oper...

Страница 18: ...s pipeline 14 8 Safety in use 1 Should close down immediately dump checkup and repair if find following conditions A Electrical machine current exceed 10 or above of rated current for a long time B Ma...

Отзывы: