5 / 16
LED Status:
FOG Green LED indicates that the generator is
producing fog.
DELAY Yellow LED indicates that the delay is
activated and won’t produce fog until it is turned
off.
FLUID VALVE Green LED indicates that the fluid
solenoid valve is on and should turn on and off
with the FOG LED.
CO2 VALVE Green LED indicates that the liquid
CO2 solenoid valve is on
Fog Output Delay:
Delay of 3 to 30 seconds. Allowing to cool down the
cold chamber of the Generator.
Fog Output adjustment:
Pressure regulator & Gauge
Max. Operating pressure 4.1 bar (60 psi)
Main Power
switch
Detachable standard remote control
See next page
Power Cord
208 or 230 VAC
Operating Pressure:
Refrigerated low pressure liquid CO input
1500 kPa (225 psi) ± 10%
Pressure Switch:
Upward position will pressurize the Fluid
Reservoir.
Downward position will depressurize
allowing to refill the Fluid
reservoir.