ICE FOG
Q
TM
User Guide, Revision A/d, May 2017
8 / 16
SETTING UP
WARNING:
When not in use ALWAYS switch off the power switch located on the back panel, or
unplug the generator.
Never install above people.
These Fog Generators must be installed in an upright position on a stable and level
surface.
Do not operate at less than 2 meters (6.5 ft.) from people.
Use in a well ventilated area.
Maximum Operating Pressure: 414 kPa / 4.1 bar / 60 psi
LIQUID
&
GAS
REQUIREMENTS
WARNING
In the European Community the gas cylinder and regulator must be
compliant with the Pressure Vessel Directive.
In North America the gas cylinder must be manufactured, inspected and
tested in accordance with U.S. Department of Transportation (DOT) 3AL
and Transport Canada (TC) 3ALM requirements.
WARNING
Only use low pressure refrigerated liquid Carbon Dioxide (CO
2
) Dewar
container. The recommended pressure should be 1500 kPa (225 psi) ±
10%.
CAUTION
To prevent gas leak and drop of pressure, ALWAYS use a neoprene washer
when connecting the regulator to the cylinder
The CO
2
gas is used as a propellant when generating Fog. Output pressure can be
adjusted by mean of the CO
2
gas regulator that you will find in the back panel of the
generator.