www.marketdirect.com.au
Ph: 1300 494 494
47
Trouble Shooting
When entering fault mode, the display will flash the LED lights to indicate the fault code. This will be indicated by:
2 long flashes of 2 seconds followed by a sequence of flashes with a 0.5 second interval. The number of quick flashes
indicates the fault code on the table below.
Times of
flashes of LED
Cause of trouble
1
Failure of second start
2
Termination of the third time of combustion
3
Power voltage out of specified range
4
Combustion chamber temperature too high during self-check period
6
Broken circuit or short-circuit of temperature sensor
7
Broken circuit or short-circuit of fuel pump
8
Broken circuit, short-circuit, or rotation clogging of fan motor
9
Broken circuit or short-circuit of glow plug
10
Ambient temperature over high before starting or furnace body temperature over
high during heating process
11
Broken circuit or short-circuit of overheating sensor
12
Broken circuit or short-circuit of control switch
13
Maintenance reminder: More than 800 hours of work time
14
Failure of controller
Protecting from Mould
Mould is very difficult to clean once a porous surface is affected. There are several ways you can prevent the
occurrence of mould on your caravan.
Never leave your camper packed away wet. If you must leave a campsite with wet canvas or a damn interior, be sure
to open and dry out your tent thoroughly at the very first opportunity when you get home. Mould can develop in just
a couple of days so don’t take the risk.
When packing up dry, it is important to check under the mattress
that there is no build-up of condensation overnight. Body heat on
a mattress can create enough temperature difference with the
exterior for moisture to form under it. If left unchecked this can
cause mould when your caravan is stored.
Содержание XT10E 2021
Страница 37: ...www marketdirect com au Ph 1300 494 494 33...
Страница 40: ...www marketdirect com au Ph 1300 494 494 36 12 Volt Main Circuit Diagram COMING SOON...
Страница 41: ...www marketdirect com au Ph 1300 494 494 37 12 Volt Switch Circuit COMING SOON...
Страница 63: ...www marketdirect com au Ph 1300 494 494 59 Trip Name Date Km Start Km Finish Cumulative Km...
Страница 65: ...www marketdirect com au Ph 1300 494 494 61 Hub Assembly...
Страница 66: ...www marketdirect com au Ph 1300 494 494 62 Trailing Arm Bushes...
Страница 90: ...www marketdirect com au Ph 1300 494 494 86 Video Tutorials COMING SOON...