www.marketdirect.com.au
Ph: 1300 494 494
39
illegal to use the appliance, and in some countries, this even makes it illegal to use the vehicle.
•
Any work involving connection or interconnecting wiring must be carried out by a licensed electrician. If the
mains cable (supply cord) is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
•
Any work involving connection or interconnecting wiring must be carried out by a licensed electrician. If the
mains cable (supply cord) is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
•
Before accessing terminals, please ensure all supply circuits are disconnected (i.e. 230 V – 240 V and 12 V) and
that the gas supply is securely turned off.
•
The operating pressure for the gas supply is 2.75 kPa (AUS – Propane) and must correspond to the operating
pressure of the appliance (see data plate).
•
LPG systems and pressure regulators must comply with the technical and administrative regulations of the
country in which the appliance is used. For your own safety it is absolutely necessary to have the complete gas
installation regularly checked by an expert (at least every 2 years). The vehicle owner is always responsible for
arranging the gas inspection.
•
Do not operate when travelling.
•
Do not operate the water heater when refueling the vehicle and when it is in the garage.
•
Items sensitive to heat (e. g. spray cans) must not be stored in the installation area, since excess temperatures
may occur there under certain circumstances.
•
During the initial operation of a brand-new appliance (or after it has not been used for some time), an amount
of fumes and a slight smell may be noticed for a short while.
Always observe the operating instructions prior to starting!
The vehicle owner is responsible for correct operation of the appliance.
Before using the product for the first time, it is essential to flush the entire water supply through with clean
warm water. Always mount the cowl cap when the water heater is not being operated! Drain the water
heater if there is a risk of frost! Warranty claims will not be accepted for frost damage.
Always remove the cowl cover prior to operating the water heater.
If connecting to a central water supply (rural or city connection) or when using more powerful pumps, a pressure
reducer must be used which prevents pressures of greater than 400 kPa occurring in the Truma UltraRapid.
Filling the Truma UltraRapid with Water
Check that the drain valve (3) and the P&T safety valve
(Fig.2a - 4) in the cold water intake are closed.
•
Close drain valve (Fig. 2 - 3). Lever in the “e”
position (close).
•
Test lever (Fig. 2a - 4a) of the pressure relief valve
(4) must be in the “close” position.
–
Open hot tap in bathroom or kitchen, with pre-
selecting mixing taps or single-lever fittings
set to “hot”.
–
Switch on power for water pump (main switch or
pump switch).
Содержание XT10E 2021
Страница 37: ...www marketdirect com au Ph 1300 494 494 33...
Страница 40: ...www marketdirect com au Ph 1300 494 494 36 12 Volt Main Circuit Diagram COMING SOON...
Страница 41: ...www marketdirect com au Ph 1300 494 494 37 12 Volt Switch Circuit COMING SOON...
Страница 63: ...www marketdirect com au Ph 1300 494 494 59 Trip Name Date Km Start Km Finish Cumulative Km...
Страница 65: ...www marketdirect com au Ph 1300 494 494 61 Hub Assembly...
Страница 66: ...www marketdirect com au Ph 1300 494 494 62 Trailing Arm Bushes...
Страница 90: ...www marketdirect com au Ph 1300 494 494 86 Video Tutorials COMING SOON...