Electrical
Problem
P
ossible Cause
Remedy
No 12 v
olt power
Main Isolator in off P
osition
Turn on main isolator
Flat Battery
Charge Battery
Faulty Battery
Replace
Main Circuit break
er tripped
Reset main circuit break
er
Loose Battery T
erminals
Tighten terminals
Damaged wiring
Find and repair/
replace
Battery not Charging
Faulty Battery
Ha
ve battery tested and replace if faulty
No mains power
Indicated b
y charger not turned on. Check mains power
, if charger still doesn
’t switch on
the charger ma
y be faulty and y
ou should contact the dealer for warr
anty or replacement.
Faulty Charger
A charger fault will be indicated b
y fast flashing on the charger control panel (Projecta
Intelli-Charge
). Contact y
our dealer for warr
anty or replacement.
Charger has o
verheated
Indicated b
y O
TP on L
CD screen and fast flashing. Ensure adequate v
entilation around
charger and allow to cool. Do not store items around the electronics. (Projecta Intelli-
Charge
)
Lights or plugs not working
Tripped circuit break
er
Reset break
er
P
oor Connection
Find and rectify
Circuit switch off
Check control panel and switch on
Not power to fridge
Indicators or parking lights not working
P
oor Connection at tr
ailer plug
Check and clean plug contacts. If pins are closed up use a knife to separ
ate the split in the
pins being sure not to widen too far
. The gap should be e
ven along the length of the pin.
In
verter not powering
P
oor Connection
Check 12v connections are tight
Main 12v switch is off
Check main rotary switch on control panel
Flat Battery
Charge battery
200A main circuit break
er
If no other 12v is a
vailable check the main 200A break
er with a multimeter or test light
150A break
er to in
verter
Check 150A break
er to in
verter using a multimeter or test light
No in
verter Output
See In
verter trouble shooting page
Circuit break
er tripping during use
Ov
erloading
Check amper
age dr
aw from appliance
Faulty Appliance
Check appliance and rectify
Battery not charging from anderson plug
Faulty Connection at plug
Check plug ensuring connections are firm
50A circuit break
er tripping
Check there are no shorts and check circuit break
er with multimeter or test light
BMS
Check BMS is correctly set and oper
ating (see manual page
)
Содержание XH 2021
Страница 33: ...www mdcusa com Ph 833 632 8721 33 Pole Layout ...
Страница 44: ...www mdcusa com Ph 833 632 8721 44 Schematics Part Numbers Hub Assembly ...
Страница 45: ...www mdcusa com Ph 833 632 8721 45 Trailing Arms and Bushes ...
Страница 72: ...www mdcusa com Ph 833 632 8721 72 Trip Name Date Miles Start Miles Finish Cumulative Miles ...