MD 500
(Models 369HE/HS/HM
)
ROTORCRAFT FLIGHT MANUAL
CSP
−
HE/HS
−
1
Emergency and
Malfunction Procedures
FAA Approved
Revision 6
3
−
28
GENERATOR MALFUNCTION
Indications:
Yellow
GEN
OUT
indicator ON and ammeter indicating zero.
Conditions:
Generator is not powering electrical bus.
Procedures:
e
Check generator (GEN) circuit breaker IN
e
Turn the generator (GEN) switch, OFF then ON to reset.
e
If GEN OUT indicator remains ON or comes back ON, pull generator cir-
cuit breaker OUT and insure generator switch is in the ON position for
the remainder of the flight.
NOTE
:
The generator switch must be in the ON position to enable the Engine Out/Low
Rotor audio warning to function as required.
e
If GEN OUT indicator remains ON, reduce electrical load to a minimum.
e
Land as soon as practical.