10. ELECTRICAL SYSTEM LIMITATIONS
Generator limits:
Maximum continuous: 66 amps
66 to 150 amps: 10 minutes
>150 amps: 2 minute limit prior to takeoff during battery recharging cycle
only.
Battery limits:
Flight following a battery overtemperature of 160
°
F (71
°
C) or above is pro-
hibited until the battery has been inspected.
2
−
11. STARTER LIMITATIONS
If ignition is not attained:
1 minute on, 1 minute off;
1 minute on, 23 minutes off;
2
−
12. FUEL SYSTEM LIMITATIONS
Fuel Specifications:
For additional information on fuels, refer to the appropriate Rolls Royce Opera-
tion and Maintenance Manual.
Primary
Jet A (ASTM D−1655); Jet A−1 (ASTM D−1655); Jet B (ASTM−D−1655)
JP−1 conforming to ASTM D−1655, Jet A or Jet A−1
JP−4 (MIL−DTL−5624); JP−5 (MIL−DTL−5624); JP−8 (MIL−DTL−83133)
Arctic Diesel Fuel DF−A conforming to ASTM D−1655, Jet A or Jet A−1
Diesel No. 1 conforming to ASTM D−1655, Jet A or Jet A−1
Peoples Republic of China RP−3.
Alternate
AVGAS/JetA, A−1, JP−5 or JP−8 mixture may be used at ambient tem-
peratures of 4
°
C and below.
Refer to Rolls Royce Operation and Maintenance Manual for AVGAS
mix, cold weather fuel and blending instructions.
Содержание MILVIZ MD530F
Страница 1: ... MD530FModel R O T O R C R A F T F L I G H T M A N U A L REGISTRATION NO SERIAL NO i ...
Страница 10: ...MV MD530F ROTORCRAFT FLIGHT MANUAL n 250 C20 2 10 ...
Страница 42: ......
Страница 65: ......
Страница 100: ......
Страница 103: ......
Страница 196: ......
Страница 219: ......
Страница 222: ......
Страница 242: ......
Страница 244: ......
Страница 257: ......
Страница 261: ...MD 500 Models 369HE HS HM ROTORCRAFT FLIGHT MANUAL CSP HE HS 1 Optional Equipment 9 ii FAA Approved Revision 6 ...
Страница 265: ......
Страница 277: ......
Страница 283: ......
Страница 304: ......
Страница 322: ......