CSP-HE/HS-1
Emergency and
Malfunction Procedures
ROTORCRAFT FLIGHT MANUAL
MD 500
(Models 369HE/HS/HM
)
Revision 6
3-1 1
FAA Approved
Procedures:
F
Twistgrip
CUTOFF
F
Starter
MOTOR UNTIL TOT IS BELOW 150
°
C
F
Fuel shut−off valve
PULL TO CLOSE
Conditions:
Engine compartment fire
Procedures:
F
Twistgrip
CUTOFF
F
Fuel shutoff valve
PULL TO CLOSE
F
BATTERY/EXT PWR switch
OFF
F
Passengers/crew
EVACUATE
If time and situation permit
:
F
Rotor brake (if installed)
APPLY
F
Secure area
HAVE PASSENGERS AND SPECTATORS
MOVE A SAFE DISTANCE FROM THE AIR-
CRAFT
F
Fire extinguisher
USE AS APPROPRIATE
ENGINE FIRE DURING FLIGHT
Conditions:
At low altitude (AGL)
Procedures:
F
Land immediately
POWER ON APPROACH AND LANDING
WITHOUT DELAY
F
Twistgrip
CUTOFF-AS SOON AS HELICOPTER IS ON
GROUND
F
Fuel shutoff valve
PULL TO CLOSE
F
BATTERY/EXT PWR switch
OFF
F
Passengers/crew
EVACUATE