Optional Equipment
Rotorcraft Hoist
ROTORCRAFT FLIGHT MANUAL
MD 500
(Models 369HE/HS/HM
)
CSP-HE/HS-1
Revision 6
9-32
FAA Approved
PART IV
NORMAL PROCEDURES
Normal Operation:
Check hoist circuit breaker IN.
Check cable cut circuit breaker IN.
Hoist operator must wear an approved safety harness (provided with hoist)
during all hoisting operations.
While in hovering flight (at speeds less than 25 mph forward, rearward, or
sideward) over hoist operations site, bring the hook over the door as the
door is opened, slide the bar latch into door slot to lock door in open posi−
tion; attach electrical connector to hoist.
Operator may move cable up or down by means of the three position switch
provided in the cargo compartment.
NOTE
:
Any time that the cable is extended, limit speed to 20 mph or less.
Prior to moving away from hoist operation site, the cable should be stowed,
electrical connector disconnected, and the door closed.
Use of the hoist for personnel is restricted to rescue and should be limited
to removal of the person from a place of peril or imminent peril to safety.