6
2-INSTALLATION INSTRUCTIONS
PRECAUTIONS REGARDING INSTALLATION
IMPORTANT!
Product installation and assembly must be carried out by qualified personnel.
The product must be installed in a suitable place for it to be regularly opened and routine maintenance to be performed.
The site must be:
t
compliant for proper operation.
t
Equipped with an adequate smoke expulsion system.
t
Equipped with ventilation intake from outside.
t
Equipped with 230V 50 Hz power supply with an EC compliant earth system.
The product must be connected to a chimney or an internal or external vertical duct that complies with the regulations in
force. The product must be positioned in such a way that the electrical socket is accessible.
IMPORTANT!
The product must be connected to a chimney or a vertical duct that can expel the smoke at the highest point of the
building.
In any case smoke derives from combustion of types of wood and if it comes in contact with or close to walls, these
can become dirty. Moreover, utmost attention is required as they are almost invisible but very hot and can cause
burns. The holes of the external air inlet and the smoke outlet pipe must be drilled before positioning the product.
THE OPERATING ENVIRONMENT
For correct operation and even distribution of heat, the product must be placed where the air required for combustion can flow.
The volume of the room should be no less than 15 m
3
.
The air must come in through permanent openings made in walls (in proximity to the product) which lead to the outside, with a minimum
cross-section area of 80 cm
2
, without the protective grilles.
These openings (air inlets) must be made in such a way that it is impossible for them to be obstructed in any way.
Air can also be drawn from adjacent rooms to the one that is to be ventilated, provided they have an external air inlet and are not used as a
bedroom or bathroom or where there is a fire hazard, such as: garages, timber storerooms, warehouses of flammable materials, observing
under all circumstances the provisions of all the applicable standards in force.
If the product is placed too close to the wall it could cause overheating and damage the plaster (yellowing, cracking,
etc.).
POSITIONING AND RESTRICTIONS
In the case of simultaneous installation with other heating appliances, provide appropriate air inlets for each one (according to the
instructions of each product).
The product cannot be installed (except for sealed or closed operation appliances with external ducted combustion
air intake):
t
in bedrooms or bathrooms;
t
in rooms where there are liquid fuel appliances with continuous or intermittent operation that draw the
combustion air from the room they are installed in;