0,5 mt.
1
2
3
0,5 mt.
2
1
3
3-5 %
2 - 3 mt. MAX
0,5 mt.
H
>
1
,5
m
t.
3
2
1
11
2-INSTALLATION INSTRUCTIONS
CONNECTIONS
CONNECTION TO THE
FLUE PIPE
CONNECTION TO AN
EXTERNAL DUCT WITH AN INSULATED
OR DOUBLE-WALL PIPE
CONNECTION TO THE FLUE
PIPE
The internal dimensions of the chimney
pipe must not exceed 20x20 cm or 20 cm
in diameter; in the event of bigger sizes
or bad chimney conditions (e.g. cracks,
poor insulation, etc.), it is advisable to fit
a stainless steel pipe of suitable diameter
throughout the length of the chimney
right to the top.
The minimum internal dimensions of the
external duct must be 10x10 cm or 10 cm
in diameter and must not exceed 20x20 cm
or 20 cm in diameter.
Only stainless steel insulated (double-wall)
pipes must be used, which are smooth on
the inside and fixed to the wall. Flexible
stainless steel pipes must not be used.
The connection between the product and
the flue or the smoke duct must not have
an inclination below 3% in the horizontal
sections, which must have a maximum
overall length of 2/3 m. The vertical section
between one T-fitting and another (angle)
must not be less than 1.5 m.
Ÿ8*/%1300'$)*./&:105 Ÿ'-6&
Ÿ*/41&$5*0/
t
Use adequate instruments to verify that there is a minimum draught of 5 Pa.
t
Set-up an inspection hole at the bottom of the chimney to perform periodic checks and cleaning, which must
be done annually.
t
The connection to the chimney must be sealed and the fittings and pipes recommended by us must be used (CE
marked in accordance with EN1856-2 with the minimum requisites: T200 and P1).
t
You must ensure that a windproof chimneypot is installed in accordance with the regulations in force.
t
This type of connection guarantees smoke expulsion even in the event of a temporary power cut.
Technical Dept. - All rights reserved - Reproduction is prohibited
Содержание GARDENIA
Страница 16: ...14 3 TECHNICAL DRAWINGS AND CHARACTERISTICS DIMENSIONS OF MARGHERITA ANDGARDENIA HYDROVERSION...
Страница 65: ......
Страница 66: ......
Страница 67: ......