PROBLEM
POSSIBLE CAUSES
REMEDY
The smoke extraction
motor does not work.
No electrical supply to the stove.
The motor is broken.
Defective electronic board.
Control panel broken.
Check the supply voltage and the
protection fuse.
Check the motor and capacitor and
replace if necessary.
Replace electronic board.
Replace the control panel.
The convection air fan
runs continuously.
Temperature sensor defective or broken.
Fan broken.
Check the operation of the sensor
and replace if necessary.
Check the operation of the motor
and replace if necessary.
Remote control does
not work (if purchased
/ optional)
Remote control batteries flat.
Remote control broken.
Replace batteries.
Replace remote control.
In the automatic
position the stove
always runs at full
power.
Room thermostat set to maximum.
Temperature sensor defective.
Control panel defective or broken.
Reset the thermostat temperature.
Check the operation of the sensor
and replace if necessary.
Check the panel and replace if
necessary.
The stove does not run
Lack of electricity supply.
Pellet sensor in lockout.
Fuse blown.
Check that the electric socket is plugged
in and that the main switch is in position
“I”.
Clear lockout by resetting the rear
thermostat,
replace the thermostat if
it happens again
.
Replace the fuse.
The stove does not
light
Make sure that the grate is clean
Check the position of the grate
Make sure that the sparkplug heats
Smoke outlet or duct blocked
Clean the grate of any incrustations or
residues of unburnt pellets.
Put the grate back in its seat.
Check and replace if necessary.
Clean the smoke outlet and/or smoke
duct
ANOMALIES RELATED TO THE PLUMBING CIRCUIT
PROBLEM
POSSIBLE CAUSES
REMEDY
No increase in
temperature with
stove in operation
1. Incorrect combustion adjustment.
2. Boiler / system dirty.
3. Insufficient stove power.
4. Poor pellet quality
1. Check recipe and parameters.
2. Check and clean the boiler.
3. Check that the stove is properly
sized for the requirements of the
system.
4. Use MCZ pellets
Condensation
in
boiler
1. Incorrect temperature setting.
2. Insufficient fuel consumption.