background image

 

INSTALLATION AND USE MANUAL 

Chapter 4

 

page

 20  

 

Installation and assembly 

        Technical service - MCZ

S.p.A. all rights reserved - Reproduction prohibited 

 

4.3. 

 

ASSEMBLY AND FEET ADJUSTMENT 

Some models require the assembly of support feet whose purpose is to 
level the stove to be well-aligned and stable. For the Wood Module, the 
feet also lift the structure to prevent the decorative frame from coming 
into contact with the floor. Correct adjustment requires the frame to be 
about  0.5 cm above the floor.  

The  feet  are  screwed  into  the  structure  base  and  can  be  installed  as 
illustrated and adjusted using a screwdriver. 

 

4.4. 

 

CERAMICS ASSEMBLY 

For  the  assembly  of  ceramics  for  each  specific  wood  stove  model, 
please  see  the  ceramics  installation  manual  in  the  latter's  packaging. 
Assembly  instructions  for  the  Modulo  product  decorative  frame  are 
included below. 

 

4.5. 

 

FRAME ASSEMBLY (WOOD MODULE) 

For  stove  frame  assembly,  after  unpacking,  remove  the  top  of  the 
stove,  unscrewing  the  four  screws  on  the  top,  place  the  frame  on  the 
structure and continue as indicated below 

 

PHASE 1 

Near and fit the lower frame supports in the slots on the lower part of 
the stove structure.  

 

PHASE 2 

Near  the  frame  and  fit  the  top  edge  of  the  structure  so  the  screws 
match the holes on the structure. Secure the frame with the fastening 
screws as illustrated.  

 

 

After  levelling  the  last tile, make sure the cornice is fastened 
correctly  to  the  structure  of  the  heater,  checking  that  the 
latter is firmly anchored.

 

 

 

Phase  2

  Match  the  frame  to  the  structure  as  illustrated  and  secure  using  the 

fastening screws and bolts 

Phase 1

 Fit the lower frame supports on 

the lower part of the structure 

Содержание ALPHA-ORION

Страница 1: ...ibited EN ANTHEA MYRIA LUNA QUASAR NADIR PULSAR SIRIO ZENIT VENUS COMETA ALPHA ORION MODULO LEGNA NuTech Renewables Ltd Unit 11 Warrenpoint Enterprise Centre Newry Road Warrenpoint Co Down BT34 3LA Te...

Страница 2: ...mSchV Art 15a B VG VKF AEAI Regensburger M nchener BStV erf llt 300 mm 500 mm Rendement 84 6 Energieeffizenz Puissance nominale Heizleistung 7 4 kW SIRIO ZENIT VENUS COMETA ALPHA ORION Prodotto confor...

Страница 3: ...ND UNPACKING 19 4 2 POSITIONING 19 4 3 ASSEMBLY AND FEET ADJUSTMENT 20 4 4 CERAMICS ASSEMBLY 20 4 5 FRAME ASSEMBLY WOOD MODULE 20 5 OPERATION 21 5 1 PRE LIGHTING WARNINGS 21 5 2 FUEL 21 5 3 STOVE USE...

Страница 4: ...tion even partial of this manual without the Manufacturer s authorisation is prohibited Manual preservation Please keep and store this manual handy If this manual should be lost or destroyed or if it...

Страница 5: ...e stack etc Therefore avoid direct contact with these parts unless wearing protective clothing or specific means such as for example heat protective gloves or cold activation devices Explain these haz...

Страница 6: ...direct or indirect to persons animals or property consequent to neglect to observe all the instructions indicated in this manual and especially concerning the installation use and maintenance warnings...

Страница 7: ...s or bathrooms or rooms where fire hazards do not exist such as garages wood sheds flammable material warehouses strictly observing that stated in current regulations Stoves may not be installed in be...

Страница 8: ...ole with minimum 150 cm free section near the stove 15 cm diameter or a 10x15cm rectangle protected by an indoor and outdoor grill The air intake must also directly communicate with the installation r...

Страница 9: ...l The use of flexible and cement fibre pipes is prohibited The smoke stack must not cross rooms where the installation of combustion devices is prohibited The use of pipes in counter slope is prohibit...

Страница 10: ...e ratio between internal dimensions must be 1 5 The recommended section for a chimney flue according to its length is listed in the table below Height m Section cm Up to 5 mt 20x30 cm or 22 cm From 5...

Страница 11: ...smoke deflector cone Permits excellent smoke exhaust Chimneypots must meet the following requisites They must have an internal section equal to that of the chimney They must have a useful output sect...

Страница 12: ...11 Massive smoke capacity 10 8 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to th...

Страница 13: ...11 2 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used QUASAR Cerami...

Страница 14: ...pe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used PULSAR Technical specification...

Страница 15: ...apacity 8 8 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used 3 2 DES...

Страница 16: ...5 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used ALPHA Technical...

Страница 17: ...g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used SIRIO Technical sp...

Страница 18: ...t 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used 3 3 MODULO LINE MODULO Technical specifica...

Страница 19: ...that foreseen The stove must always be kept upright and exclusively moved with a trolley Pay careful attention that the door and its glass are protected from mechanical collisions that could jeopardis...

Страница 20: ...tallation manual in the latter s packaging Assembly instructions for the Modulo product decorative frame are included below 4 5 FRAME ASSEMBLY WOOD MODULE For stove frame assembly after unpacking remo...

Страница 21: ...spray in the original colour see stove accessories Do not stay near the stove and as previously mentioned ventilate the room The smoke and the smell of paint will vanish after about one hour of operat...

Страница 22: ...by combustion based on the use of unsuitable fuels cause damage to the stove and the chimney they cause pollution and can significantly compromise your health 5 3 STOVE USE 5 3 1 LOADING THE FUEL To...

Страница 23: ...cally sets the quantity of incoming primary and secondary air 5 3 2 3 Model adjustments PULSAR NADIR Combustion air regulation in these model is slightly different than the previous in that primary an...

Страница 24: ...loading method is adopted even in subsequent product use To obtain nominal power place the load of wood indicated in the technical specifications table in the combustion chamber chapter 3 Stove autono...

Страница 25: ...rohibited 5 4 EMERGENCY TREATMENT If for any reason the stove fire needs to be suddenly and quickly put out or a fire in the chimney flue needs to be put out proceed as follows If time allows remove t...

Страница 26: ...Glass since it is not elastic can break This type of glass does not burst or shatter but if it should break due to the above it will only crack 6 1 2 Cleaning upper calorite deflectors They do not re...

Страница 27: ...taken from blocks of stone and then worked Therefore veins colour variations or other characteristics are natural parts of the stone and should not be considered defects It is important to clean caref...

Отзывы: