background image

 

INSTALLATION AND USE MANUAL 

Introduction

 

page

 4  

 

Introduction 

       Technical service - MCZ

S.p.A. all rights reserved - Reproduction prohibited 

 

INTRODUCTION 

 

Dear customer, 

We  would  like  to  thank  you  for  your  choice  of  MCZ 
products.  We  are  sure  that,  with  use,  you  will 
appreciate  the  quality  of  an  attentively  designed  and 
tested  product.  Our  goal  is  to  combine  technology 
with easy use and, above all, safety. 

 

For best stove operations and to fully enjoy the 
heat  and  sense  of  well  being  it  will  spread 
throughout  your  home,  we  suggest  you 
carefully  read  this  booklet  before  use;  please 
contact  your  dealer  for  full  assistance  in 
resolving any doubts or problems. 

 

Congratulations  on  your  choice  and  remember,  the 
stove 

MUST NEVER

 be used by children who should 

always be kept at a safe distance from your stove!  

Revisions to the publication 

In  order  to  improve  the  product,  the  Manufacturer 
reserves  the  right  to  modify  and  update  this 
publication without prior notice. 

Reproduction, even partial, of this manual without the 
Manufacturer's authorisation is prohibited. 

Manual preservation. 

 

Please keep and store this manual handy. 

 

If this manual should be lost or destroyed, or if it 
is  in  poor  condition,  ask  for  a  copy  from  your 
retailer  or  directly  from  the  manufacturer, 
providing product identification data. 

How to read the manual 

 

An  essential  item  or  one  that  requires  specific 
attention is published in  

“bold”. 

 

“Script”  is  used  to  invite  the  user  to  review  the 
illustrations  or  check  other  manual  sections  that 
may provide more in-depth explanations.

 

 

NOTE

:  the  “NOTE”  provides  the  reader  with 

additional information on the subject. 

These  symbols  signal  specific  messages  in  this 
booklet 

 

 

WARNING

This  warning  symbol  found  in  various 
points  in  this  manual  indicates  that  the 
user  should  carefully  read  and  understand 
the  message  to  which  it  refers  since

 

neglect  to  follow  these  instructions 
could cause serious stove damages or 
injury to the user. 

 

 

INFORMATION

This

 

symbol 

intends 

to 

emphasise 

important  information  for  good  stove 
operations.  Failure  to  observe  these 
instructions  could  jeopardise  product  use 
and operations may be unsatisfactory 

 

 

Содержание ALPHA-ORION

Страница 1: ...ibited EN ANTHEA MYRIA LUNA QUASAR NADIR PULSAR SIRIO ZENIT VENUS COMETA ALPHA ORION MODULO LEGNA NuTech Renewables Ltd Unit 11 Warrenpoint Enterprise Centre Newry Road Warrenpoint Co Down BT34 3LA Te...

Страница 2: ...mSchV Art 15a B VG VKF AEAI Regensburger M nchener BStV erf llt 300 mm 500 mm Rendement 84 6 Energieeffizenz Puissance nominale Heizleistung 7 4 kW SIRIO ZENIT VENUS COMETA ALPHA ORION Prodotto confor...

Страница 3: ...ND UNPACKING 19 4 2 POSITIONING 19 4 3 ASSEMBLY AND FEET ADJUSTMENT 20 4 4 CERAMICS ASSEMBLY 20 4 5 FRAME ASSEMBLY WOOD MODULE 20 5 OPERATION 21 5 1 PRE LIGHTING WARNINGS 21 5 2 FUEL 21 5 3 STOVE USE...

Страница 4: ...tion even partial of this manual without the Manufacturer s authorisation is prohibited Manual preservation Please keep and store this manual handy If this manual should be lost or destroyed or if it...

Страница 5: ...e stack etc Therefore avoid direct contact with these parts unless wearing protective clothing or specific means such as for example heat protective gloves or cold activation devices Explain these haz...

Страница 6: ...direct or indirect to persons animals or property consequent to neglect to observe all the instructions indicated in this manual and especially concerning the installation use and maintenance warnings...

Страница 7: ...s or bathrooms or rooms where fire hazards do not exist such as garages wood sheds flammable material warehouses strictly observing that stated in current regulations Stoves may not be installed in be...

Страница 8: ...ole with minimum 150 cm free section near the stove 15 cm diameter or a 10x15cm rectangle protected by an indoor and outdoor grill The air intake must also directly communicate with the installation r...

Страница 9: ...l The use of flexible and cement fibre pipes is prohibited The smoke stack must not cross rooms where the installation of combustion devices is prohibited The use of pipes in counter slope is prohibit...

Страница 10: ...e ratio between internal dimensions must be 1 5 The recommended section for a chimney flue according to its length is listed in the table below Height m Section cm Up to 5 mt 20x30 cm or 22 cm From 5...

Страница 11: ...smoke deflector cone Permits excellent smoke exhaust Chimneypots must meet the following requisites They must have an internal section equal to that of the chimney They must have a useful output sect...

Страница 12: ...11 Massive smoke capacity 10 8 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to th...

Страница 13: ...11 2 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used QUASAR Cerami...

Страница 14: ...pe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used PULSAR Technical specification...

Страница 15: ...apacity 8 8 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used 3 2 DES...

Страница 16: ...5 g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used ALPHA Technical...

Страница 17: ...g s Flue pipe Up to 5 mt 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used SIRIO Technical sp...

Страница 18: ...t 20x30 cm 22 Between 5 and 7 mt 20x20 cm 20 Over 7 mt 18x18 cm 18 Note A stove is an intermittent combustion device Data may vary according to the fuel used 3 3 MODULO LINE MODULO Technical specifica...

Страница 19: ...that foreseen The stove must always be kept upright and exclusively moved with a trolley Pay careful attention that the door and its glass are protected from mechanical collisions that could jeopardis...

Страница 20: ...tallation manual in the latter s packaging Assembly instructions for the Modulo product decorative frame are included below 4 5 FRAME ASSEMBLY WOOD MODULE For stove frame assembly after unpacking remo...

Страница 21: ...spray in the original colour see stove accessories Do not stay near the stove and as previously mentioned ventilate the room The smoke and the smell of paint will vanish after about one hour of operat...

Страница 22: ...by combustion based on the use of unsuitable fuels cause damage to the stove and the chimney they cause pollution and can significantly compromise your health 5 3 STOVE USE 5 3 1 LOADING THE FUEL To...

Страница 23: ...cally sets the quantity of incoming primary and secondary air 5 3 2 3 Model adjustments PULSAR NADIR Combustion air regulation in these model is slightly different than the previous in that primary an...

Страница 24: ...loading method is adopted even in subsequent product use To obtain nominal power place the load of wood indicated in the technical specifications table in the combustion chamber chapter 3 Stove autono...

Страница 25: ...rohibited 5 4 EMERGENCY TREATMENT If for any reason the stove fire needs to be suddenly and quickly put out or a fire in the chimney flue needs to be put out proceed as follows If time allows remove t...

Страница 26: ...Glass since it is not elastic can break This type of glass does not burst or shatter but if it should break due to the above it will only crack 6 1 2 Cleaning upper calorite deflectors They do not re...

Страница 27: ...taken from blocks of stone and then worked Therefore veins colour variations or other characteristics are natural parts of the stone and should not be considered defects It is important to clean caref...

Отзывы: