PHYSICAL DATA
ELECTRICAL DATA
Heat Pump (R410A)
Heat Pump (R410A)
Model
5RT90BR
5RT120BR
5RT150BR
5RT180BR
Power supply
V/Ph/Hz
380-415/3N~/50
Max continuous current (Comp)
A
26.0
16.5/16.5
19.0/19.0
26.0/26.0
Full load current (FLA, Comp)
A
21.0
12.2/12.2
15.0/15.0
21.0/21.0
Locked rotor current (LRA, Comp)
A
111.0
74.0/74.0
101.0/101.0
111.0/111.0
WIRE CONNECTION
• All electrical work must be carried out by quali
fi
ed electrician and accordance with local supply requirement and
associate regulation.
PE
a
b
c
d
g
e
f
(2) Wiring connection to unit
Route the power supply wires and control wire through the knockout holes in the unit.
Remove the service panels and connect the units power supply wires to terminal block inside the control box, as
shown.
Model
5RT90BR
5RT120BR
5RT150BR
5RT180BR
Refrigerant
R410A
Refrigerant charge
kg
6.1
5.8/5.8
7.2/7.2
8.7/8.7
Evaporator air
fl
ow
CFM
3300
4300
5650
6600
L/S
1557
2029
2667
3115
External static pressure
mmAq
15
21
Pa
147
206
Condenser air
fl
ow
CFM
8230
6000/6000
6050/6050
6450/6450
L/S
3884
2831/2831
2855/2855
3044/3044
Control
Wired Rooftop Controller
Control wire length (Standard/Max) : Size
m : mm
2
15 / 100 : 3
Compressor (Type/Quantity)
Scroll/1
Scroll/2
Scroll/2
Scroll/2
Air
fi
lter (Type/Quantity)
Washable Saranet/2
Air
fi
lter dimension (Length x Width x Thickness)
mm
880 x 467 x 4
1126 x 385 x 4
1126 x 435 x 4
1497 x 392 x 4
a. Power supply
d.
Unit
b. Main switch/fuse
(
fi
eld supply)
e.
Remote control
f.
Connection wiring for
unit & remote controller
c. Power supply
wiring for unit
g.
Earth
Method for connecting electric wire
Before connecting the wire, consult the electric power company of jurisdiction.
(1) The entire wiring diagram of unit
The equipment ful
fi
ls the requirements in EN 61000-3-11 and is subject to conditional connection to the mains. It may be
connected in consultation with the supply authority. The equipment may only be connected to a mains supply with a system
impedance of less than the value stated in table below. The system impedance in the interface point may be obtained from
the supply authority.
If the mains supply has a higher system impedance, short voltage dips may appear when the equipment is started or during
operation. This may in
fl
uence or disturb the operation of other apparatuses, e.g.
fl
ickering lamps, especially those
connected to the same supply mains.
Model
Maximum impedance (Z
max
), ohm
5RT90BR
0.22
5RT120BR
0.23
5RT150BR
0.21
5RT180BR
0.21
IM 1 5RTBR-1209(0)-EN.indd 13
IM 1 5RTBR-1209(0)-EN.indd 13
1/14/10 11:37:25 AM
1/14/10 11:37:25 AM
Содержание ROOFTOP R08019034483
Страница 2: ......
Страница 22: ...6 8 1 1 OFF R410A 1 1975 1...
Страница 23: ...6 9 a b...
Страница 25: ...6 11 f a b c 5RT90BR d 4 4 5RT90BR e 1 4 3000 1200 1200 1200 A B C A 70 B 2C C 2 X...
Страница 32: ...6 18 40 C 2 5RT90BR i ii R410A iii iv R410A R410A R410A R410A R410A R410A...
Страница 33: ...6 19 ON OFF 3 3 5RT90BR 5RT120 150 180BR...
Страница 34: ...6 20...