High Pressure Protection
Flashing every 0.5s
Off
Low Pressure Protection
Off
Flashing every 0.5s
Outdoor Ambient Temp. Sensor
Malfunction
Off
On
Defrosting Temp. Sensor Malfunction
On
Off
Table 3-2: Main Board LED Display Instruction
4
Names and Functions of Remote Controller Buttons
NOTE:
This remote controller is applicable to many units. Some buttons unavailable in this unit such as “TURBO”,
“BLOW”, “LIGHT”, “TEMP”
, HEALTH|SAVE
and
would not
described below.
Fig. 4-1
1.
“ON/OFF” button
After powering the unit, when the unit is off press the “ON/OFF” button to start the unit. And when the unit
is on, press the same button to turn it off.
2.
“Mode” button
Press this button, and the unit will switch to the mode you want. Press it once, and the mode will be changed in a
regular order as AUTO –COOL –DRY –FAN – HEAT.
AUTO
;
COOL
;
DRY
;
FAN
;
“
”
8