                                                      www.mcohome.com                                        User Manual

 

MCOHome Technology Co., Ltd     

     

 

5

 

 

 

High temperature protection    (For MH7H-EH Electrical Heating ONLY) 

        When external temperature sensor detect the temperature value

55

, device will open high 

temperature  protection,  electric  heating  will  be  forced  off,  and  high  temperature  protection  icon 

displays. 

        When external temperature sensor detect the temperature value

50 

, device will return to 

normal work, high temperature protection icon disappears. 

 

Anti-freeze protection function: (Optional) 

 

In shutdown interface:   

    When  the  built-in  temperature  sensor  detect  the  temperature  value

5

,  device  will  open 

anti-freeze  protection,  electric  heating  will  be  forced  open,  and  anti-freeze  protection  icon 

displays. 

When  the  built-in  temperature  sensor  detect  the  temperature  value

,  device  will  turn 

off anti-freeze protection and return to normal work, anti-freeze icon disappears. 

Note: If MH7 thermostat do not connect with an external temperature sensor, it will only display 

the  indoor  temperature  icon;  If  MH7  thermostat  connect  with  an  external  temperature  sensor,  it 

will  display the indoor temperature and  high temperature protection icon; When it is  under high 

temperature protection, high temperature protection icon flickers. 

 

Humidity display operation   

          In  normal  working  interface,  long  press  S1+S5  buttons  and  enter  into  humidity  display 

interface, when press S1+S5 buttons again, it will back to the normal interface.

 

 

Z-Wave Operation 

 

Adding & Removing of Z-Wave network 

        In  normal  working  interface,  press  &  hold  S4  to  enter  interface  for  adding  or  removing  of 

Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press 

S4  once,  device  will  enter learning  mode to  get a node  ID. If  adding  is succeed, a node  ID will 

display on the screen in a few seconds.   

    A node ID can always inform us whether the device   

is in the network or not. 

Note: Follow the same steps to remove the device   

from the network. When removed, the device will   

restore its factory setting. 

After adding, turn off the device and then turn it on. Now the device is ready to be operated 

by controller/ gateway in Z-Wave network.   

 

 

Association Group 

Thermostat supports 1 association group (0x01), which can include only one Node ID. 

Week\Periods 

Period 1 

Period 2 

Period 3 

Period 4 

Mon~Fri 

5:00      28

 

7:00      24

 

17:00    28

 

22:00    24

 

Sat~Sun 

5:00      28

 

9:00      24

 

17:00    28

 

22:00    24

 

Содержание MH7H-WH

Страница 1: ...H 5A MH7H EH 16A Self Consumption 1W External Temp Sensor optional NTC R25 15K B25 50 3550K Working Environment 0 50 0 90 RH Non condensation Temperature Setting 5 37 41 99 Adjustable Dimension 86 86...

Страница 2: ...ice is well mounted power on and it is ready to operate L N COM NC NO L N Passive com Normal open Normal close L N COM L N Valve NC NO T T T T Sensor Sensor L N T T L N Elec OUT Sensor 1 Passive Wall...

Страница 3: ...is 5 37 41 99 Then press S4 or S5 can adjust the value Press S3 or wait 25 seconds without any key operation will save the setting and return back to the normal operation interface Auto Mode The chan...

Страница 4: ...o the normal working interface In this time vacation mode icon displays and device will follow the setting Long press S2 again will end vacation mode and resume to normal work vacation mode icon will...

Страница 5: ...display the indoor temperature and high temperature protection icon When it is under high temperature protection high temperature protection icon flickers Humidity display operation In normal working...

Страница 6: ...o Away heating mode Vacation Users can set these 4 modes via COMMAND_CLASS_THERMOSTAT_MODE And COMMAND_CLASS_BASIC can switch among Heating mode Energy saving heating mode COMMAND_CLASS_THERMOSTAT_SET...

Страница 7: ...24 hours P05 EH negative deadband 1 5 3 0 0 10 0 0 18 WH negative deadband 0 5 1 0 0 10 0 0 18 P06 EH positive deadband 0 0 00 0 0 10 0 0 18 WH Temp positive deadband 0 5 1 0 0 10 0 0 18 P07 Anti fre...

Страница 8: ...t OC OC OF OC Celsius OF Fahrenheit P18 Restore factory setting Display 53 Password 55 00 99 Change 53 to 55 and press S3 to confirm Please use this procedure only when the network primary controller...