High temperature protection (For MH7H-EH Electrical Heating ONLY)
When external temperature sensor detect the temperature value
≥
55
℃
, device will open high
temperature protection, electric heating will be forced off, and high temperature protection icon
displays.
When external temperature sensor detect the temperature value
<
50
℃
, device will return to
normal work, high temperature protection icon disappears.
Anti-freeze protection function: (Optional)
In shutdown interface:
When the built-in temperature sensor detect the temperature value
≤
5
℃
, device will open
anti-freeze protection, electric heating will be forced open, and anti-freeze protection icon
displays.
When the built-in temperature sensor detect the temperature value
>
8
℃
, device will turn
off anti-freeze protection and return to normal work, anti-freeze icon disappears.
Note: If MH7 thermostat do not connect with an external temperature sensor, it will only display
the indoor temperature icon; If MH7 thermostat connect with an external temperature sensor, it
will display the indoor temperature and high temperature protection icon; When it is under high
temperature protection, high temperature protection icon flickers.
Humidity display operation
In normal working interface, long press S1+S5 buttons and enter into humidity display
interface, when press S1+S5 buttons again, it will back to the normal interface.
Z-Wave Operation
Adding & Removing of Z-Wave network
In normal working interface, press & hold S4 to enter interface for adding or removing of
Z-Wave network. Before device added into network, “- - -” will display on the screen. Then press
S4 once, device will enter learning mode to get a node ID. If adding is succeed, a node ID will
display on the screen in a few seconds.
A node ID can always inform us whether the device
is in the network or not.
Note: Follow the same steps to remove the device
from the network. When removed, the device will
restore its factory setting.
After adding, turn off the device and then turn it on. Now the device is ready to be operated
by controller/ gateway in Z-Wave network.
Association Group
Thermostat supports 1 association group (0x01), which can include only one Node ID.
Week\Periods
Period 1
Period 2
Period 3
Period 4
Mon~Fri
5:00 28
℃
7:00 24
℃
17:00 28
℃
22:00 24
℃
Sat~Sun
5:00 28
℃
9:00 24
℃
17:00 28
℃
22:00 24
℃