PTR5100-5500W   Thermos t at   I nstructions 

See overleaf for further setting up information 

This thermostat is a combination model allowing you to  

choose between 3 different models. A, AF and F model. 

A  model:      air onl y , with built in sensor 

AF model:   air & floo r , with both built in and remote sensor 

F model:      floor onl y , with remote sensor 

Menu Settings

( P art I) 

Menu #

01

Sensor selection

Switching differential

Air temperature calibrate
Floor temperature calibrate

Temperature readout 

(AF model only ) 

Maximum floor temperature

(AF model only) 

(PTR5100BL model only) 

Backlight turning-on time 

Temperature format

Clock format 

24H (default),  12H

Program time delay

02

03

04

05

06

07

08

09

10

11

Features description 

Features Explanation 

Adjustment 

1 °C(default),  2 °C.........10°C

-1°C = decrease 1°C,  1°C =  increase 1°C...

  5s  ,  10s   , 15s   ,20s (default) , 25s, 30s.

A= to show air temperature,  F=to show floor temperature,

  A--F = to show both in 5 second intervals 

  40°C(default)

   30 seconds(default)  On= always on, OFF= always off

  C  or    F

A, AF, F

(press up or down button to adjust)

-1°C = decrease 1 °C,  1°C =  increase 1 °C...

This product should be installed by a qualified electrician. 

Please Note: one of the following error messages will appear if one of these problems occur: 

The numbers of degree difference before switching.  

The default is 1°C which means the thermostat will  

switch the heating on 0.5°C below the set temperature  

and will turn it off 0.5°C above the set temperature.  

With a 2°C differential, the heating will switch on 1°C 

below the set temperature and will switch off 1°C 

above the set temperature.   

This is to calibrate air temperature if required. 
This is to calibrate floor temperature if required. 

This gives more time for user to set the programmes 

before reverting back to standard display 

This gives option to choose to show air temperature, 

floor temperature or to show both floor & air in interval. 

This is to protect the floor surface. 

This is to set the backlight turning-on time. User  

can also set the backlight always on or off. 

This allows users to select between °C or °F.  

12/24 Hour clock format selection 

Buttons and LCD display

Button / Icon 

Description

Menu button

Auto/Vacation mode selection

Increase the set value

Decrease the set value

Set the time and week days

M

The buttons are locked.

Heating is turned on

Button / Icon  Description

Auto mode

Vacation mode

Temporary temperature override

Frost protection activated

Programmes number

AUTO

Temporary

Frost protection

E0, meaning the internal sensor is broken, short-circuit or not working properly.
E1, meaning the  floor sensor is broken, short-circuit, not connected, or not working properly.

on= activated,  off= deactivated

This is to avoid room temperature goes below 5°C 

Ver.1.1 

P

P

Press  buttton             t o   T urn on/o f f the thermostat. When thermostat is turn ed off, the LCD will only display “OFF”. Now press and hold button         for 3 seconds 

to bring up a configuration menu. In this mode, press button 

 to cycle through the menus.

 

M

M

P

Turning on/off thermostat
Program button

Confirm settings

Remarks: The thermostat will return to standby mode after 20 seconds of inactivity. (Using         button will also exit the menu setting)